RADT-29 Toward intraoperative dosimetric guidance for GammaTile: An exploratory workflow integrating intraoperative imaging and open-source 3D Slicer software
Jacob Lee, Javier Navarro Rueda, Clara Ferreira
Key points
From the paper's conclusion- We propose and develop a proof-of-concept intraoperative workflow for real-time GammaTile dosimetry assessment, integrating intraoperative imaging with custom-built 3D Slicer module software designed for GammaTile.
Abstract
GammaTile cesium-131 collagen tiles deliver immediate postoperative radiation therapy for brain tumors by lining the resection cavity, delivering a steep dose fall-off to target residual disease while sparing healthy tissue. However, intraoperative changes following tumor resection introduce geometric uncertainty between preoperative planning and the as-implanted tile configuration, and no real-time tool currently exists to verify dose coverage before dural closure. We propose and develop a proof-of-concept intraoperative workflow for real-time GammaTile dosimetry assessment, integrating intraoperative imaging with custom-built 3D Slicer module software designed for GammaTile. The workflow comprises preoperative MRI, tumor resection, physical placement, intraoperative CT, deformable registration to the preoperative plan, HR-CTV segmentation, real-time tile dosimetry, confirmatory intraoperative CT, followed by minor adjustments before closure as needed. To evaluate the imaging stage, we 3D-printed a brain phantom based on an intraoperative MRI case and acquired four CT trials, alongside exploratory imaging with 3T MRI, Artec Spider II, and TRIOS 3Shape, with intraoperative ultrasound under continued evaluation. CT yielded the most consistent visualization and manageable workflow-burden, compared to MRI and ultrasound. The 3D Slicer software enabled phantom-image import, drag-and-drop tile/seed placement with rotation and translation, TG-43-based dose calculation modeling fixed per-seed/tile, and real-time 2D/3D isodose visualization, adding an estimated just 20–40 minutes to a 5–9 hour full surgical procedure. Limitations include a single-phantom cohort and dependence on CT availability, needing further analysis of imaging modality and in-patient studies. GammaTile is a procedure in which clinicians must make irreversible placement decisions, and current practice offers no intraoperative dosimetric feedback to guide tile positioning before dural closure. Clinicians have accordingly called for additional intraoperative guidance despite the workflow cost it imposes. This framework offers a low-cost pathway toward closing that gap, showing great promise that adjacent intraoperative guidance could become a scalable, standard-of-care add-on for every GammaTile procedure.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- BrachyAtlas: Patient-Specific Virtual Planning for Intracavitary Cesium-131 Brachytherapy with Tile Placement, Dose Calculation, and Modeled Neuroanatomical ExposuremedRxiv · 2026
- GammaTile® Brachytherapy as Spatially Fractionated Radiation Therapy for Postoperative Brain Cancer: A Paradigm for Precision Intracranial Radiotherapy.Cancers · 2026
- RADT-08 Multicenter outcomes and patterns of intracranial failure after resection plus intraoperative cesium-131 collagen tile-based brachytherapy (GammaTile) for recurrent glioblastoma: a GTM-101 registry analysisNeuro-Oncology · 2026
- EP09.29 Image-guided intraoperative radiotherapy for resectable brain metastases: Prospective evaluation of dosimetric accuracy and clinical outcomesNeuro-Oncology · 2026
- Initial Outcomes of GammaTile Brachytherapy From a Single Institution: A Case Series.Cureus · 2026
- TMOD-25 An In Vitro Platform to Assess Combined Radiation-Drug Efficacy in Glioblastoma Using Tile-Based Radiation Therapy and Organotypic Brain Slice CulturesNeuro-Oncology · 2026