From the paper's conclusion
  • The multicenter OMX-EFS-01 trial (NCT06533163) is an exposure-time escalation pilot trial evaluating safety and early clinical activity of RT combined with escalating exposure times of low-intensity oscillatory magnetic therapy (OMT) in patients with temozolomide-resistant glioblastoma (GBM).

Abstract

Background Spinning oscillating magnetic fields were shown to disrupt mitochondrial electron transport, thereby generating reactive oxygen species and inducing apoptosis. The multicenter OMX-EFS-01 trial (NCT06533163) is an exposure-time escalation pilot trial evaluating safety and early clinical activity of RT combined with escalating exposure times of low-intensity oscillatory magnetic therapy (OMT) in patients with temozolomide-resistant glioblastoma (GBM). Methods OMX-EFS-01 is planned to enroll up to 30 patients with newly-diagnosed GBM lacking MGMT promoter hypermethylation after maximal safe resection and with KPS ≥70. All patients receive standard RT (60 Gy/30 fractions) and daily OMT. Exposure times are escalated in two-hour increments from 4 to a maximum of 8 hours per day once the first two weeks are tolerated. The primary endpoint is safety as per incidence of device-related adverse events (AE). Secondary endpoints include radiographic response (mRANO), progression-free survival (PFS), overall survival (OS) and quality of life. Results As of May 18, 2026, thirteen patients were enrolled (median age: 61 years, range 32-72). Of all G ≥ 2 AEs (n = 28), 15 (53.6%) events were deemed at least possibly OMT-related, including 5 grade 3 events. There were no exposure time-limiting toxicities and no device-related deaths. The median time of OMT application was 6.8 (range 1.2-14.5) months. Median device compliance to a minimum daily application of 4 hours was 94 % (range 3-98%). Device use is ongoing in five patients. After a median follow-up of 10.2 months, median PFS was 9.0 (range 4.2-12.9) months. Median OS has not been reached, with one death at 14.5 months. Conclusions Interim data from the ongoing OMX-EFS-01 trial support feasibility and safety of RT combined with OMT. Further enrollment of up to 30 patients is now planned.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers