Long-term change in measured penile length after primary inflatable penile prosthesis without a standardized postoperative cycling protocol: an opportunistically ascertained single-surgeon cohort of 223 returning patients.
Edward L Gheiler, Boris V Klopukh, Domingo Luis, Brandon Arriaga, Emily M Luis, Jorge Septien, Jennifer E Tews, Fernando J Bianco
Urological Research Network Corp., Miami Lakes, FL 33016, United States. · Dr. Kiran C. Patel College of Osteopathic Medicine, Nova Southeastern University, Fort Lauderdale, FL 33328, United States.
Key points
From the paper's conclusion- Among patients who returned for long-term care, the measured fully inflated penile length was greater than the intraoperative placement-time value. The opportunistic and uncontrolled design, incomplete capture, rater-timepoint confounding, measurement limitations, and device-state differences preclude causal or mechanistic conclusions. These findings do not support prosthesis placement as a cosmetic lengthening procedure or use of the exploratory predictor for clinical decisions.
Abstract
INTRODUCTION: Long-term penile length data after inflatable penile prosthesis placement derive largely from small rehabilitation series. We evaluated long-term change in measured penile length and transverse width, potential predictors, and device use after primary implantation without a prescribed rehabilitation protocol. METHODS: This retrospective cohort analysis included 223 returning patients with a preoperative stretched-flaccid length, a fully inflated intraoperative placement-time length, and a fully inflated office length recorded at least 24 months after primary implantation. The primary outcome was the within-state placement-to-follow-up difference. Secondary analyses included the mixed-state difference from preoperative stretched-flaccid length, tape-measured mid-shaft width, exploratory predictors, device use, and prespecified subgroups. RESULTS: The mean follow-up was 49.0 months and the mean age was 74.2 years. Long-term fully inflated length exceeded the fully inflated placement-time length by 1.28 cm (95% CI, 1.12-1.45; P < .0001). Using a pragmatic 0.5-cm descriptive threshold, 70.0% increased, 25.6% were stable, and 4.5% decreased. The 2.04-cm difference from preoperative stretched-flaccid length mixed different measurement states and was not interpreted as biological gain. Mean tape-measured mid-shaft width changed by 0.13 cm (95% CI, 0.08-0.17), but the method did not support mechanistic inference. In the complete 2021-2023 operative registry, 160 of 628 eligible implants (25.5%) were represented. Of 223 patients, 213 (95.5%) reported sexual activity at follow-up. CONCLUSIONS: Among patients who returned for long-term care, the measured fully inflated penile length was greater than the intraoperative placement-time value. The opportunistic and uncontrolled design, incomplete capture, rater-timepoint confounding, measurement limitations, and device-state differences preclude causal or mechanistic conclusions. These findings do not support prosthesis placement as a cosmetic lengthening procedure or use of the exploratory predictor for clinical decisions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Penile length after inflatable penile prosthesis implant: a single-center, high-volume experience.Asian journal of andrology · 2026
- Primary gender-affirming inflatable penile prosthesis insertion has a prolonged learning curve.The journal of sexual medicine · 2026
- The outcomes of non-surgical and surgical penile augmentation procedures: a systematic review and meta-analysis.International journal of impotence research · 2026
- Long-Term Satisfaction With Inflatable Penile Prosthesis Using the Satisfaction Survey for Inflatable Penile Implant in a Veteran Population.Andrology · 2026
- Subcutaneous penile silicone sleeve implants for penile augmentation: a systematic review and meta-analysis.International journal of impotence research · 2026
- Manometry-based comparison of ex-vivo versus in-vivo inflation profiles among antibiotic-coated inflatable penile prostheses and the impact of progressive modeling in instances of concomitant Peyronie's disease.Urology · 2026