Case report: revision surgery for a fractured femoral stem using an ESOP prosthesis - analysis of the diagnostic work-up, treatment strategy, and long-term outcome.
Łukasz Dutka, Julian Dutka, Adrian Szczecina, Adam Solarz, Dominik Kostarczyk, Mateusz Bukowczan
Department of Orthopedic and Trauma Surgery, Żeromski Specialist Hospital in Kraków, Osiedle Na Skarpie 66, 31-913 Kraków, Poland. · Department of Orthopedic and Trauma Surgery, Stefan Żeromski Specialist Hospital in Kraków, Osiedle Na Skarpie 66, 31-913 Kraków, Poland.
Key points
From the paper's conclusion- In carefully selected cases, this technique may represent a valuable alternative to extensive revision surgery.
Abstract
Femoral stem fracture following total hip arthroplasty is a rare but serious complication that usually requires removal of both implant fragments and implantation of a longer revision stem. However, this procedure may be associated with substantial bone loss and an increased risk of intraoperative and postoperative complications. A 58-year-old man underwent cementless total hip arthroplasty with a Zweymüller-type stem in 2008. Five years later, the stem fractured. During revision surgery, the proximal fragment was removed, whereas the well-fixed distal fragment could not be safely extracted. It was therefore retained, and only the proximal component of a modular ESOP (anatomical modular cementless femoral stem) short stem was implanted. The postoperative course was uneventful. At 13-year follow-up, the patient remains pain-free, with full hip function, and no radiographic evidence of implant loosening. In carefully selected cases, this technique may represent a valuable alternative to extensive revision surgery.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Successful management of a proximal femoral comminuted fracture occurring after total hip arthroplasty in a small-breed dog.The Journal of veterinary medical science · 2026
- Extraction of a Fractured, Well-Fixed Femoral Stem Using a Lateral Cortical Window Technique in Revision Hip Arthroplasty: A Case Report.Journal of orthopaedic case reports · 2026
- Primary Total Knee Arthroplasty Using Revision-Type Stems for Distal Femoral Bone Compromise Following Previous Fracture Fixation: A Report of Two Cases and Narrative Review.Cureus · 2026
- Early Nontraumatic Periprosthetic Femoral Fracture After Total Hip Arthroplasty: A Case Report.Case reports in orthopedics · 2026
- [Translated article] Use of uncemented modular diaphyseal stems in salvage hip replacement after cut-out failure of cephalomedular fixation for extracapsular hip fractures. Monocentric series.Revista espanola de cirugia ortopedica y traumatologia · 2026
- Case Report: Total hip arthroplasty via the direct anterior approach using a cementless revision stem without corrective osteotomy for fibrous dysplasia.Frontiers in surgery · 2026