Revista espanola de cirugia ortopedica y traumatologia

[Translated article] Use of uncemented modular diaphyseal stems in salvage hip replacement after cut-out failure of cephalomedular fixation for extracapsular hip fractures. Monocentric series.

I Martínez Pérez, C López-Orosa

Servicio de Cirugía Ortopédica y Traumatología, Hospital Universitario Príncipe de Asturias, Alcalá de Henares, Madrid, Spain. Electronic address: irenemartperez@gmail.com. · Unidad de Cadera y Rodilla, Servicio de Cirugía Ortopédica y Traumatología, Hospital Universitario de Fuenlabrada, Fuenlabrada, Madrid, Spain.

Case report · n=10

Key points

From the paper's conclusion
  • Fourteen cases were recorded, nine after Gamma3® nailing and five after Intertan® nailing. The posterolateral approach was the most commonly used (10 cases). Eight total hip replacements, three double mobility replacements, and six bipolar hemiarthroplasties were implanted. At 30 days, 92.9% were able to walk indoors with technical support. During the first year, six patients (42.8%) had complications related to the implant: three periprosthetic fractures, one acetabular erosion, and three dislocations. No patients died during hospitalization or at 30 days; one patient (7.1%) died within a year.

Abstract

BACKGROUND AND OBJECTIVE: There are different treatments for cut-out failure after intramedullary nailing in hip fractures. Salvage with hip arthroplasty is an accepted method in frail elderly patients and in cases of articular cartilage damage or compromised bone stock precluding re-osteosynthesis. However, this is not without complications (10-66%) due to its complexity. MATERIAL AND METHODS: A single-center retrospective case series of patients treated with salvage arthroplasty using an uncemented modular diaphyseal fixation stem (Arcos® system, Zimmer Biomet). Minimum follow-up was 1 year. RESULTS: Fourteen cases were recorded, nine after Gamma3® nailing and five after Intertan® nailing. The posterolateral approach was the most commonly used (10 cases). Eight total hip replacements, three double mobility replacements, and six bipolar hemiarthroplasties were implanted. At 30 days, 92.9% were able to walk indoors with technical support. During the first year, six patients (42.8%) had complications related to the implant: three periprosthetic fractures, one acetabular erosion, and three dislocations. No patients died during hospitalization or at 30 days; one patient (7.1%) died within a year. DISCUSSION AND CONCLUSION: Prosthetic salvage after cut-out with uncemented modular diaphyseal stems is a complex surgery with a significant risk of complications, especially dislocation and periprosthetic fracture. These implants allow the deficient proximal areas to be by-passed and restore the length, version, and offset, making them a possible alternative in selected patients, although not without complications. EVIDENCE LEVEL: Level IV.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers