EP9.4 Imaging Adjustment for Pelvic Coronal Plane Kinematics During Gait: A Reliability Study of Femoral Head Coverage
PD Dr med Nils Becker, BS Lucas Kim, MD Renato Locks, DC, MS, MPhil Gregory Roytman, BS John Slevin, MD Andrew Jimenez, MD Aidin Eslam-Pour
Key points
From the paper's conclusion- Discussion This study demonstrated high inter- and intra-rater reliability for adjusted radiographs that incorporated dynamic motion data to assess femoral head coverage during gait.
Abstract
Purpose Gait-related coronal pelvic motion may alter femoral head coverage but is not reflected in conventional static radiographs. Wearable inertial measurement units (IMUs) enable quantification of pelvic kinematics during walking, which can be used for standard imaging adjustment. It was hypothesized that femoral head coverage measurements obtained from adjusted standing pelvic radiographs would demonstrate high inter- and intra-rater reliability. Methods A prospective single-institutional hip preservation registry with 129 cases was screened for unilateral femoro-acetabular impingement syndrome (FAIS) cases, of which 10 patients (20 hips) were selected. The registry includes supine and standing radiographs and motion capture using IMUs. The coronal pelvic kinematics used during walking included contralateral peak pelvic drop and compensatory, ipsilateral femoral adduction. Both dynamic parameters were incorporated into standard standing pelvic radiographs through image adjustment. Two raters independently measured the lateral center-edge angle (LCEA), acetabular index (AI), femoro-epiphyseal acetabular roof index (FEAR), and extrusion index (EI) to determine inter- and intra-correlation coefficients (ICCs). Results The mean peak pelvic drop on the asymptomatic hip was 5.2° ± 1.6° (2.2° to 7.1°), with compensatory femoral adduction of -2.8° ± 5.1° (-13.8° to 4.2°) on the affected side. Inter-rater reliability had ICCs of 0.71 to 0.97 in the first round and 0.86 to 0.96 in the second round for femoral head coverage parameters on the adjusted radiographs, while intra-rater agreement showed ICCs ranging from 0.77 to 0.94 for rater 1 and 0.73 to 0.97 for rater 2. Discussion This study demonstrated high inter- and intra-rater reliability for adjusted radiographs that incorporated dynamic motion data to assess femoral head coverage during gait. Further research is needed to identify factors affecting coronal pelvic kinematics and to examine its possible surgical implications and effect on outcomes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- FP1.7 Is the Lateral Center-Edge Angle Truly Static? A Conceptual Framework for Dynamic Acetabular CoverageJournal of Hip Preservation Surgery · 2026
- TP1.4 Frame-by-Frame Analysis of Dynamic Acetabular Coverage During Operative-Stance in Femoroacetabular ImpingementJournal of Hip Preservation Surgery · 2026
- EP1.52 Gait Asymmetry Patterns in Femoroacetabular Impingement: Association with Operative-Stance Acetabular Coverage ReclassificationJournal of Hip Preservation Surgery · 2026
- EP9.17 Patients with Cam- And Pincer-Type Hip Impingement Demonstrate Similar Magnitude of Peak Pelvic DropJournal of Hip Preservation Surgery · 2026
- EP9.15 Coronal Pelvic Drop as a Compensatory Mechanism in Acetabular Over-Coverage: Associations with Dynamic Lateral Center-Edge Angle Normalization, Patient-Reported Function, and Reoperation RiskJournal of Hip Preservation Surgery · 2026
- TP5.1 Acetabular Over-Coverage Predicts Revision After Femoroacetabular Impingement Surgery: Association of Static and Dynamic Lateral Center-Edge Angle Classification with Reoperation RiskJournal of Hip Preservation Surgery · 2026