EP9.17 Patients with Cam- And Pincer-Type Hip Impingement Demonstrate Similar Magnitude of Peak Pelvic Drop
Mr Nicholas Lee, Mr Lucas Kim, Dr Nils Becker, Dr Gregory Roytman, Mr John Slevin, Dr Renato Locks, Dr Aidin Eslam Pour, Dr Andrew Jimenez
Key points
From the paper's conclusion- During walking, peak pelvic drop was 5.0° ± 1.4 on the symptomatic hip and 4.8° ± 1.6 on the asymptomatic hip for cam-type FAIS which was similar to peak pelvic drop in patients with pincer-typer FAIS (symptomatic: 4.5° ± 1.6 and 5.1° ± 2.0 for pincer-type FAIS, respectively (p > 0.05).
Abstract
Purpose Femoroacetabular impingement syndrome (FAIS) is a common cause of groin pain in young adults. Classically, cam-and pincer-type FAI are based on static radiographic images, but FAIS is a dynamic pathology that may be affected by pelvic dynamics during activity. It was hypothesized that cam- and pincer-type FAIS would demonstrate altered peak pelvic drop in the coronal plane. Methods Motion-capture, demographic, and patient-reported outcome measurements (PROMs) data were analyzed for all patients with unilateral FAIS from a prospectively collected hip arthroscopy database. Motion capture during walking was performed using inertial measurement units (Movella, Xsens, El Segundo, CA, USA), and the peak pelvic drop of both hips was assessed. The following PROMs were analyzed: International Hip Outcome Tool (iHOT-12), Hip Outcome Score–Sports Subscale (HOS-SS), Patient Reported Outcomes Measurement (PROMIS) Physical Function, PROMIS Pain Interference, PROMIS Depression, and PROMIS Anxiety. Pelvic kinematics and PROMs were compared between cam- and pincer-type FAIS using an unpaired Student's t-test. In addition, coronal peak pelvic motion during walking was correlated to lateral center-edge angle (LCEA) and alpha angle using Spearman`s rank coefficient test. Radiographic definitions used were cam, Alpha angle ≥55° and pincer-type, LCEA ≥40°. Results In total 83 hips in 83 patients were included with 38 hips of cam-type and 45 pincer-type FAIS. During walking, peak pelvic drop was 5.0° ± 1.4 on the symptomatic hip and 4.8° ± 1.6 on the asymptomatic hip for cam-type FAIS which was similar to peak pelvic drop in patients with pincer-typer FAIS (symptomatic: 4.5° ± 1.6 and 5.1° ± 2.0 for pincer-type FAIS, respectively (p > 0.05). Preoperative PROMs were also similar between cam- and pincer-type FAIS patients (p > 0.05). In addition, preoperatively, LCEA and alpha angle did not show a significant correlation to peak ipsilateral and contralateral pelvic drop (p>0.05). Discussion Peak pelvic drop did not differ between patients with cam- versus pincer-type FAIS and did not show a significant correlation to preoperative LCEA or alpha angle. Further studies are warranted to analyze the impact of peak pelvic drop on postoperative recovery and outcomes in patients undergoing hip arthroscopy surgery.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- EP9.16 Increased Pelvic Drop and Femoral Adduction Are Associated with Improved Preoperative Outcomes In Patients Undergoing Hip Arthroscopy For Treatment Of Femoroacetabular Impingement: A Prospective StudyJournal of Hip Preservation Surgery · 2026
- EP3.6 Sit-to-Stand Adaptations in Pre-Operative Cam-Type Femoroacetabular Impingement: A Kinematic and Coordination AnalysisJournal of Hip Preservation Surgery · 2026
- FP14.7 Proposing the Femoroacetabular Contribution Index Obtained by EOS Edge Measurements in Three Positions: Association with One-Year Outcomes Following Hip Arthroscopy for FAISJournal of Hip Preservation Surgery · 2026
- Three-position EOS Edge assessment of pelvic mobility and the Femoroacetabular Contribution Index: Association with 1-year outcomes after hip arthroscopy for femoroacetabular impingement syndrome: A pilot study.Journal of experimental orthopaedics · 2026
- TP9.1 The Presence of Trendelenburg Gait is Not Associated with Radiographic Measurements or Preoperative Outcomes in Patients Undergoing Hip Arthroscopy for the Treatment of Femoroacetabular ImpingementJournal of Hip Preservation Surgery · 2026
- EP1.52 Gait Asymmetry Patterns in Femoroacetabular Impingement: Association with Operative-Stance Acetabular Coverage ReclassificationJournal of Hip Preservation Surgery · 2026