Journal of Hip Preservation Surgery

FP8.8 Deep Learning–Based Automated Detection of Periprosthetic Osteolysis After Primary Total Hip Arthroplasty on Standard Radiographs: A Multicenter Retrospective Study

Dr Riccardo Giai Via, Dr Matteo Giachino, Prof Alessandro Massè, Dr Nicolas Bonin, Dr Guido Barducci

Observational · n=1,039

Key points

From the paper's conclusion
  • Conclusions Deep learning–based detection of periprosthetic osteolysis in Gruen zone 1 on standard radiographs is feasible and demonstrates stable cross-dataset performance in a real-world multicenter setting.

Abstract

ICLA08 - AI and 3D Simulations: Trustworthy Clinical Partners or Tech Hype? Auditorium B (BMCC Level 1), October 8, 2026, 14:00 - 16:00 Background Total hip arthroplasty (THA) is one of the most successful procedures in modern orthopedics. However, aseptic loosening secondary to periprosthetic osteolysis remains a leading cause of long-term implant failure. Radiographic follow-up relies primarily on standard anteroposterior (AP) pelvic radiographs, but early osteolytic changes are often subtle and subject to significant inter-observer variability. Automated image analysis using deep learning may provide a reproducible and objective tool to support radiographic assessment. The aim of this study was to develop and validate a deep learning algorithm for the automatic detection of periprosthetic osteolysis specifically in Gruen zone 1 in patients undergoing primary cementless THA. Methods We conducted a retrospective multicenter observational study including 1,183 primary cementless press-fit THAs performed in 1,039 patients between 2017 and 2024 at two high-volume European centers. Only standard AP pelvic radiographs with a minimum follow-up of 24 months were included. Osteolysis in Gruen zone 1 was independently annotated by experienced orthopedic surgeons, with consensus in cases of disagreement. A two-stage deep learning pipeline was implemented. First, a segmentation network (DeepLabV3 with ResNet-50 backbone) was trained to automatically identify and extract the region corresponding to Gruen zone 1. Second, a binary classification model based on transfer learning (ResNet-18) was trained to detect the presence or absence of osteolysis within the segmented region. To evaluate generalizability, cross-dataset validation was performed by training the model on one institutional cohort and testing it on independent datasets, including a separate cohort from the same center. Performance was assessed using Matthews Correlation Coefficient (MCC) as the primary metric, along with precision, recall, and F1-score. Model interpretability was explored using Grad-CAM activation maps. Results The segmentation network demonstrated stable convergence and good qualitative overlap with manual annotations, enabling reliable extraction of standardized regions of interest. In cross-dataset validation experiments, the classification model achieved MCC values ranging from 0.43 to 0.62. Recall reached up to 0.81, indicating good sensitivity in detecting osteolysis in Gruen zone 1. Performance remained consistent across independent cohorts, suggesting robustness to inter-center variability in imaging acquisition. Grad-CAM visualization confirmed that model predictions were primarily driven by radiographically plausible features located at the bone–implant interface. Conclusions Deep learning–based detection of periprosthetic osteolysis in Gruen zone 1 on standard radiographs is feasible and demonstrates stable cross-dataset performance in a real-world multicenter setting. This approach may serve as a supportive tool for radiographic follow-up of cementless THA, enhancing reproducibility without replacing clinical judgment.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers