FP7.6 Thick MPR CT: Simulating Standing Pelvic Tilt for the Evaluation of Acetabular Coverage in Patients with Borderline Hip Dysplasia
Dr Cristian Feeley, Dr Claudio Rafols, Dr Juan Monckeberg, Dr Jorge Madariaga, Dr Gonzalo Delgado
Key points
From the paper's conclusion- Notably, AWI values were consistently higher in supine radiographs compared to standing radiographs, although this difference did not reach statistical significance (n=16 vs n=62; p>0.142) Conclusion In borderline hip dysplasia, most acetabular coverage parameters are comparable between standing radiographs and simulated standing CT.
Abstract
ICLB07 - The Digital Surgeon: Practical Tools and Navigation Basics for Your Everyday Practice, Session Room 12 (BMCC Level 3), October 8, 2026, 14:00 - 16:00 Background Treatment decisions in borderline hip dysplasia (BHD) rely heavily on small differences in acetabular coverage measurements. The reliability of radiographic parameters in this setting remains uncertain. Purpose The purpose of this study was to compare acetabular coverage measurements between standing radiographs and simulated standing CT in patients with BHD. Methods Symptomatic patients with BHD (LCEA 18°–25°) were prospectively evaluated with standing AP pelvic radiographs and CT using a low-dose protocol. Pelvic tilt on CT was adjusted to match the standing radiograph. Thick MPR reconstructions were used to assess acetabular coverage. LCEA, Tönnis angle, AWI, and PWI were measured independently by three observers. Agreement between methods was analyzed using paired t-tests and Pearson correlation. Results Seventy-two paired measurements were analyzed. LCEA was lower on radiographs compared with CT (22.5° ± 5.8° vs 24.9° ± 5.8°), with a mean difference of −2.4° ± 5.6° (p < 0.001; r = 0.53). No significant differences were observed for the Tönnis angle (p = 0.840), AWI (p = 0.412), or PWI (p = 0.130), with moderate to strong correlations across these parameters. LCEA showed the greatest inter-observer variability. Notably, AWI values were consistently higher in supine radiographs compared to standing radiographs, although this difference did not reach statistical significance (n=16 vs n=62; p>0.142) Conclusion In borderline hip dysplasia, most acetabular coverage parameters are comparable between standing radiographs and simulated standing CT. However, LCEA is consistently underestimated on radiographs and shows higher variability, which may affect surgical decision-making. Furthermore, the trend toward higher AWI values in supine positioning suggests that weight-bearing status influences coverage assessment Low-dose simulated standing CT provides a reproducible complementary assessment in cases where measurements are borderline.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- EP4.1 The Low-Volume Acetabulum: A CT-Based Method for Characterizing a Variant of Acetabular Dysplasia with Normal Lateral Center-Edge AnglesJournal of Hip Preservation Surgery · 2026
- The impact of functional sagittal pelvic tilt on CT-based hip dysplasia diagnostics in adults: a cross-sectional 3D simulation study.Acta orthopaedica · 2026
- EP1.48 Comparison of 2D versus 3D measurements of Lateral Center Edge Angle in Patients with Femoroacetabular Impingement Syndrome and Hip Instability: A study of 754 hipsJournal of Hip Preservation Surgery · 2026
- EP1.39 Comparison of methods for assessment of the sagittal orientation of the acetabulumJournal of Hip Preservation Surgery · 2026
- FP1.7 Is the Lateral Center-Edge Angle Truly Static? A Conceptual Framework for Dynamic Acetabular CoverageJournal of Hip Preservation Surgery · 2026
- TP3.3 Lateral Center-Edge Angle Measurements on Computed Tomography Are Higher Compared To Measurements On Plain Radiograph But Alpha Angle and Tönnis Angle Are Similar: A Systematic Review and Meta-AnalysisJournal of Hip Preservation Surgery · 2026