Body Height and Stentgraft Diameter Drive Thrombus Formation After Frozen Elephant Trunk Repair: A Risk-Focused Analysis.
Joseph Kletzer, Stoyan Kondov, Mario Lescan, Alexandar Dimov, Tim Berger, Martin Czerny, Maximilian Kreibich
Department of Cardiovascular Surgery, Heart Centre Freiburg University, Faculty of Medicine, Albert-Ludwigs-University of Freiburg, Freiburg, Germany; Faculty of Medicine, University of Freiburg, Freiburg, Germany. Electronic address: joseph.kletzer@uniklinik-freiburg.de. · Department of Cardiovascular Surgery, Heart Centre Freiburg University, Faculty of Medicine, Albert-Ludwigs-University of Freiburg, Freiburg, Germany; Faculty of Medicine, University of Freiburg, Freiburg, Germany.
Key points
From the paper's conclusion- Post-FET thrombus risk is highest when a disproportionately large stentgraft is implanted in a short-statured patient; reduced intraprosthetic blood velocity may represent a contributing hemodynamic mechanism, a hypothesis-generating finding that requires prospective validation.
Abstract
BACKGROUND: Intraluminal thrombus formation is an increasingly recognized complication after frozen elephant trunk (FET) repair. This study aims to identify the key factors driving thrombus risk, and to characterize the prognostic impact of thrombus on long-term survival. METHODS: Retrospective single-center analysis of 458 patients undergoing FET repair between 2013 and 2024. Parameters were evaluated for association with new intraluminal thrombus formation using Fine-Gray competing risk regression. Thrombus risk was visualized using a height-stentgraft diameter risk heatmap. Estimated intraprosthetic blood velocity was analyzed by receiver-operating-characteristic analysis and restricted cubic splines. RESULTS: Sixty patients (13.1%) developed new intraluminal thrombus during a median follow-up of 3.2 years (IQR 1.1-5.5). In multivariable analysis, the standardized stentgraft-to-patient-height-ratio was independently associated with new thrombus formation (HR 1.55 [95% confidence interval 1.11-2.16]; p=0.009), alongside fresh frozen plasma transfusion (HR 1.46 [95% CI 1.00-2.13]; p=0.049). The risk-heatmap demonstrated highest adjusted thrombus risk in short-statured patients receiving large-diameter stentgrafts. Estimated intraprosthetic blood velocity was significantly lower in patients who developed thrombus; an optimal velocity threshold of 14.4 cm/s (area under the curve 0.644; sensitivity 82.8%, specificity 43.2%) was associated with a 3-fold higher thrombus rate below vs. above this threshold (16.1% vs. 5.0%). Maximum thrombus diameter was an independent predictor of death within the thrombus subgroup (HR 1.130 [1.041-1.227] per mm; p=0.004). CONCLUSIONS: Post-FET thrombus risk is highest when a disproportionately large stentgraft is implanted in a short-statured patient; reduced intraprosthetic blood velocity may represent a contributing hemodynamic mechanism, a hypothesis-generating finding that requires prospective validation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Initial Surgical Experience of a Novel Frozen Elephant Trunk Without Distal Stent for Acute Type A Aortic Dissection.Annals of thoracic surgery short reports · 2026
- Aortic morphology and fenestration-related leak in fenestrated frozen elephant trunk: A cohort study.Interdisciplinary cardiovascular and thoracic surgery · 2026
- Floating thrombus in an ascending aortic graft presenting with acute upper limb ischemia after ascending aorta–femoral bypass: a case reportJournal of Cardiothoracic Surgery · 2026
- Predicting Post-TEVAR Endoleaks: A Pre-operative Hemodynamic Risk Factor from Patient-Specific Fluid-Structure Interaction Simulations.Annals of biomedical engineering · 2026
- True Lumen Guided Stent Sizing Predicts Distal Aortic Remodeling After ATAAD Repair.Annals of vascular surgery · 2026
- Association between stent graft landing zone angle and aneurysm remodelling after total arch replacement with frozen elephant trunk for distal aortic arch aneurysm.Interdisciplinary cardiovascular and thoracic surgery · 2026