Conduction System Pacing correction of pacemaker induced cardiomyopathy made it simple despite T wave memory at implant
L Ayala Valani, D Fakim, F G Ayala Valani, S Cote, F Bounames, F Ayala Paredes
Key points
From the paper's conclusion- Conclusion In CSP pacemaker upgrades, isoelectric ST segments and a positive T wave in lateral leads, even if rarely seen (19,5%), are associated with successful CSP implants (as in non paced patients); but negative T waves at implant turn positive in at least half or more of the cases, 6-8 weeks after (T wave memory carried from previous paced rhythm).
Abstract
Introduction Successful conduction system pacing (CSP) implants can be achieved using ECG qualitative criteria in lateral precordial leads (V5-V6): Presence of a S wave, of an isoelectric ST segment, and a positive T wave polarity. However, these criteria do not always work when a pacemaker induced cardiomyopathy dependent patient is upgraded to CSP, as T wave memory alters normal repolarization. A super response of resynchronisation is defined as >15% of left ventricular ejection fraction (LVEF) absolute increase at follow-up. Methods All patients receiving a CSP device, with a paced pre-implant ECG, were analyzed. Different ECG features were analyzed. Inter-peak V6-V1 values was used as gold standard and a 6-8 weeks post implant ECG was also obtained to ascertain resolution of T wave memory. A subset of patients had a LVEF assessment performed at follow-up. Results From a 5-year cohort of 697-consecutive patients (pts), 125 were CSP-upgrades due to pacemaker induced cardiomyopathy (17,9%). Mean-age was 77.4 y.o. (±0.2 years; range 22-94y.o.). Mean QRS was 178ms (range 114-248ms) before CSP attempt. Post implant mean-QRS was 140ms (range 90-202ms).The interpeak V6-V1 could not be measured in 50-pts (40%). A V6-V1 interpeak interval greater than 33ms was achieved in 38% of pts, and no association with any of the repolarization ECG markers to ascertain success was found. Most patients had a negative T wave post implant (81,5%); in those patients, T waves become positive (T wave memory) at 6-8 weeks post implant-ECG in 52% of cases, meaning negative T waves alone cannot indicate successful or failed CSP at implant. However, depolarization markers could help in these patients, as the presence of a S wave in precordial lateral leads had an accuracy of 80% to predict an inter-peak V6-V1 > 33ms; (sensitivity 75%, specificity 83%, PPV 69% and NPV 87%, p=0,0067). A subset of 15 of these pts presented a hyper response to CSP resynchronisation (LVEF >20% increase in absolute values), and 13 of these 15 pts presented with an S wave in V5-V6 at implant (see figure). Conclusion In CSP pacemaker upgrades, isoelectric ST segments and a positive T wave in lateral leads, even if rarely seen (19,5%), are associated with successful CSP implants (as in non paced patients); but negative T waves at implant turn positive in at least half or more of the cases, 6-8 weeks after (T wave memory carried from previous paced rhythm). Ideally current of injury, interpeak V6-V1 and transition patterns while thresholds should guide these implants. Depolarization ECG markers could also be used to guide these CSP implants (as presence of a S wave in lateral leads and initial ‘r’ wave in V1); a presence of an S wave in V5-V6 at implant could be a marker of hyper response to CSP resynchronisation.CSP PICPM correction FAP
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Conduction system versus biventricular pacing upgrades in pacing-induced cardiomyopathy: a reconstructed individual patient data meta-analysisEuropean Heart Journal · 2026
- Predicting Persistent Left Ventricular Dysfunction After Cardiac Resynchronization Therapy Upgrade in Pacing-Induced Cardiomyopathy.Journal of clinical medicine · 2026
- Safety and efficacy of conduction system pacing in dual-chamber pacemakers in a CRT-indicated population: primary analysis of the CORE-CPP studyEP Europace · 2026
- Non-Invasive Methods for Identifying Electrical Responders to Conduction System Pacing Cardiac Resynchronization Therapy.Pacing and clinical electrophysiology : PACE · 2026
- Learning by failing: conduction system pacing and decrease in left ventricular ejection fraction identified at implantEuropean Heart Journal · 2026
- Mid-Term and Long-Term Clinical Events with Conduction System Pacing Versus Biventricular Pacing in HFrEF with Wide QRS: A Systematic Review and Meta-Analysis of Randomized Controlled Trials with Trial Sequential Analysis.Journal of clinical medicine · 2026