Mid-Term and Long-Term Clinical Events with Conduction System Pacing Versus Biventricular Pacing in HFrEF with Wide QRS: A Systematic Review and Meta-Analysis of Randomized Controlled Trials with Trial Sequential Analysis.
Juan Munoz-Moreno, Carlos Diaz-Arocutipa, Carlos Espiche-Salazar, Jacob McAuliffe, Raymond L Benza, Amin Yehya, Johanna Contreras, Erich L Kiehl
Department of Internal Medicine, Macon and Joan Brock Virginia Health Sciences at Old Dominion University, Norfolk, VA 23507, USA. · Unidad de Revisiones Sistemáticas y Meta-Análisis (URSIGET), Vicerrectorado de Investigación, Universidad San Ignacio de Loyola, Lima 15024, Peru.
Key points
From the paper's conclusion- Conclusions: In this meta-analysis of RCTs predominantly evaluating left bundle branch area pacing, CSP was associated with a lower risk of long-term HFH compared with BiVP in HFrEF with a wide QRS, although the evidence remains limited by the small number of available trials.
Abstract
Background/Objectives: Conduction system pacing (CSP) has emerged as a more physiological alternative to biventricular pacing (BiVP) in heart failure with reduced ejection fraction (HFrEF) and wide QRS, but recent randomized controlled trials (RCTs) have yielded discordant results. This meta-analysis aimed to compare CSP with BiVP for clinical events and functional recovery in HFrEF. Methods: MEDLINE, Embase, and Cochrane Library were searched for RCTs through 15 April 2026. Primary outcomes were all-cause mortality (ACM) and heart failure hospitalization (HFH) at mid-term (6-12 months) and long-term (>12 months) follow-up. Random-effects meta-analyses and Trial Sequential Analysis (TSA) were performed. Results: Eleven RCTs comprising 12 reports and 1073 patients were included. CSP showed no significant difference in mid-term ACM (RR 0.72; 95% CI 0.21 to 2.49; p = 0.605) or HFH (RR 0.97; 95% CI 0.52 to 1.81; p = 0.918). At long-term follow-up (three RCTs; n = 312), CSP showed a non-significant trend toward ACM reduction (RR 0.34; 95% CI 0.11 to 1.06; p = 0.063; low-certainty evidence) and a significant, TSA-supported reduction in HFH (RR 0.30; 95% CI 0.16 to 0.58; p < 0.001; moderate-certainty evidence). At 6 months, CSP improved LVEF (MD 2.84%; 95% CI 0.74 to 4.93; p = 0.008) and reduced QRS duration (MD -9.97 ms; 95% CI -18.57 to -1.37; p = 0.023), with NYHA improvement at 12 months (MD -0.31; 95% CI -0.50 to -0.11; p = 0.002). Conclusions: In this meta-analysis of RCTs predominantly evaluating left bundle branch area pacing, CSP was associated with a lower risk of long-term HFH compared with BiVP in HFrEF with a wide QRS, although the evidence remains limited by the small number of available trials. The observed trend toward lower long-term ACM should be considered hypothesis-generating. Larger, adequately powered RCTs with longer follow-up are needed to confirm these findings and determine whether CSP provides sustained clinical benefit over BiVP.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Conduction system vs. biventricular pacing in heart failure with reduced ejection fraction: a meta-analysis of randomized controlled trials.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026
- Conduction system pacing vs. biventricular pacing for cardiac resynchronization therapy in heart failure: a systematic review and meta-analysis considering randomized controlled trials and observational studies.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026
- Conduction system pacing vs biventricular pacing in heart failure patients undergoing cardiac resynchronization therapy: an updated grade-assessed systematic review and meta-analysis of randomized controlled trials.Expert review of medical devices · 2026
- Conduction system pacing vs right ventricular pacing: a clinical meta-analysis of randomized controlled trialsEuropean Heart Journal · 2026
- Conduction System Pacing Versus Biventricular Pacing for Cardiac Resynchronization Therapy: A Systematic Review and Meta-Analysis of Randomized Controlled Trials.Journal of arrhythmia · 2026
- Conduction System Pacing for Resynchronization Therapy in Heart Failure: A Meta-Analysis of Randomized Controlled Trials.JACC. Asia · 2026