Impact of right ventricular pacing burden on shocks in patients with implantable cardioverter defibrillators
H Iwakawa, M Middeldorp, A Puvrez, S Kakarla, J Shroff, T Baykaner, E Fu, A Kroman,
Key points
From the paper's conclusion- These results suggest that a mixed intrinsic and paced ventricular rhythm may be associated with an increased risk of shock.Figure
Abstract
Background High burden of right ventricular pacing (RVP) may have a proarrhythmic effect in patients with implantable cardioverter defibrillators (ICDs). Purpose To assess how increased RVP burden impacts the incidence of shocks in ICD patients using a large real-world registry. Methods In a multicentre retrospective study utilizing a vendor-neutral remote monitoring (RM) platform, we included ICD patients with data on RVP burden and the date of shock delivery from January 2015 to November 2025. Patients with cardiac resynchronization therapy were excluded. The RVP burden (%RVP) for each patient was extracted from the initial transmission via a vendor-neutral remote monitoring platform. Regular RM logs recorded the date of each shock delivered. Results Among 36,528 patients with ICDs, the mean age was 63±13 years, and 30.2% were female. The total number of transmissions was 873,997, with a median of 15 per patient [7–29]. The median %RVP was estimated at 0.07% [0.00–1.00%], and the mean left ventricular ejection fraction was 40±15%. During a median follow-up of 3.9 [1.75–6.44] years, 4835 (13.2%) patients received shocks. Of these, 76.0% received anti-tachycardia pacing before the initial shock therapy. Multivariable Cox proportional hazards models were constructed, adjusting for age, sex, HF, and single- or dual-chamber device. Hazard ratios (HRs) for the initial shock occurrence in %RVP increase with %RVP up to 80% relative to %RVP < 1% (1-5%, HR 1.40 [1.30–1.52]; 5-10%, HR 1.32 [1.10–1.59]; 10-40%, HR 1.36 [1.18–1.58]; 40-80%, HR 1.35 [1.10–1.65]). By contrast, in ICD patients with very high RVP dependence (≥ 95%), the HR drops compared to those with %RVP < 1% (HR 0.71 [0.55–0.90]) (Figure). Conclusions Increased RVP burden was associated with a higher shock rate in patients with ICDs, whereas extremely high RVP dependence was not. These results suggest that a mixed intrinsic and paced ventricular rhythm may be associated with an increased risk of shock.Figure
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- High right ventricular pacing burden is associated with heart failure following leadless pacemaker implantationsEuropean Heart Journal · 2026
- Real-world evaluation of the positive predictive value and transmission burden of a novel implantable cardiac monitor with a remote reprogramming capability: insights from a single-center experienceFrontiers in Cardiovascular Medicine · 2026
- Long-term outcomes of subcutaneous implantable cardioverter defibrillators: the French nationwide HONEST studyEuropean Heart Journal · 2025
- Intrinsic versus conventional antitachycardia pacing for ventricular tachycardia: a systematic review and meta-analysisEuropean Heart Journal · 2026
- Invasive Assessment of Right Ventricular Dysfunction Predicts Periprocedural Outcomes in Patients Undergoing Unplanned Ventricular Tachycardia AblationJournal of Cardiovascular Electrophysiology · 2026
- Cardiopulmonary exercise performance in physiologic versus conventional pacingEuropean Heart Journal · 2026