Artificial intelligence enhanced ECG to detect reduced LVEF: clinical significance of false positive and false negative AI-ECG classifications
R Mistrulli, A D Anthony Demolder, R H Robert Herman, A R Adam Rafajdus, A I Andrej Iring, A M Ana Moya, M B Marta Belmonte, P P Pasquale Paolisso,
Key points
From the paper's conclusion- The aim of the present study was to investigate the clinical and prognostic implications of AI-ECG misclassifications, I.e. false positive (FP) and false negative (FN), using a previously validated AI-ECG algorithm to detect reduced LVEF (<50%) at echocardiography.
Abstract
Background Artificial intelligence has been shown to enhance the diagnostic capabilities of the electrocardiogram (AI-ECG), enabling the detection of reduced left ventricular ejection fraction (LVEF). The aim of the present study was to investigate the clinical and prognostic implications of AI-ECG misclassifications, I.e. false positive (FP) and false negative (FN), using a previously validated AI-ECG algorithm to detect reduced LVEF (<50%) at echocardiography. Methods The study population included an independent retrospective cohort of 528 patients (age 68 [56–77] y, 40% women), which consisted of four matched groups according to the concordance between paired AI- ECG predictions and Simpson’s biplane LVEF assessments: true negative (TN), FP,FN, and true positive (TP). Sttudy outcomes included a composite endpoint of cardiovascular death and hospitalization for heart failure, and, development of reduced LVEF (<50%) during follow-up in patients with normal LVEF (FP, TN) at baseline. Results At baseline, LVEF was normal in FP (55%) and TN (56%) patients and impaired in FN (45%) and TP (40%) ones (p<0.001). In contrast, global longitudinal strain (GLS) was preserved only in TN (18%) but progressively worsened across FP (14%), FN (14%), and TP (10%) ones (p<0.001). During median follow-up of 4.5 years (IQR: 2.8–6.5y), the composite endpoint occured in 59 (13%) patients with significantly lower incidence in the TN versus the other three groups (log-rank p<0.001). In multivariable Cox analysis, impaired LVEF or GLS, and higher age emerged as only independent predictors of the composite endpoint (all p < 0.05). During follow-up, a total of 49 out of 131 (37%) FP versus only 12 out of 130 (9%) TN patiens developed overt systolic dysfunction (LVEF < 50%) (p < 0.001). The major causes of LVEF decline were valvular heart- (28.6%) or coronary artery disease (23,2%) and atrial fibrillation (26.8%). In Cox regression analysis, AI-ECG classification was independent predictor of future drop in LVEF (HR 3.78; 95% CI 1.74–8.23; P=0.001) while GLS was not (NS) (Figure 1,2). Conclusions AI-ECG misclassifications are clinically relevant. The FP group has increased risk to develop overt LV dysfunction with adverse outcome, warranting close clinical follow-up. The FN classification is associated with worse outcome driven by LV dysfunction not recognized by AI-ECG, but fortunately, the prevalence of FN in the models is low.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Detecting low left ventricular ejection fraction from ECG using an interpretable and scalable predictor-driven framework: a model development and validation studyEClinicalMedicine · 2026
- Multicentre validation of an AI model for detection of reduced left ventricular ejection fractionEuropean Heart Journal · 2026
- Vectorelectrocardiography-based algorithm for screening tool of reduced ejection fraction and left ventricular hypertrophyEuropean Heart Journal · 2026
- Artificial intelligence-enabled electrocardiography for estimating left ventricular filling pressureEuropean Heart Journal · 2026
- Artificial intelligence–enhanced electrocardiography for detection of subclinical left ventricular dysfunction in cancer survivorsEuropean Heart Journal · 2026
- Artificial Intelligence–Enhanced Electrocardiogram Models for Detection of Left Ventricular DysfunctionJACC Advances · 2026