Vectorelectrocardiography-based algorithm for screening tool of reduced ejection fraction and left ventricular hypertrophy
N Hein, A Schwarz, S Wolfsteller, E Poyo Medina, N Frey, H Steen, F Andre, A Passow,
Key points
From the paper's conclusion- Our study evaluated the diagnostic performance of a vectorcardiography (VCG)-based analysis enhanced by artificial intelligence (AI) as a screening method for identifying patients with reduced LVEF and LVH.
Abstract
Background Early diagnosis of reduced left ventricular ejection fraction (LVEF) and left ventricular hypertrophy (LVH) remains challenging, particularly in settings with limited access to advanced imaging. Both phenotypes are associated with substantial morbidity and mortality. Our study evaluated the diagnostic performance of a vectorcardiography (VCG)-based analysis enhanced by artificial intelligence (AI) as a screening method for identifying patients with reduced LVEF and LVH. Methods In this single-centre, prospective case-control study, 280 individuals were included: patients with reduced LVEF (<40%), patients with LVH (left ventricular mass > 55 g/m2), and healthy controls. All participants underwent cardiac magnetic resonance imaging and VCG recording. The AI-based algorithm analysed a total of 583 parameters. Relevant features were identified using the Mann–Whitney–Wilcoxon test (low p-values). Bayes’ theorem was applied to update prior probabilities and calculate posterior probabilities for reduced LVEF and LVH in comparison to the control group. Results Among 280 participants, 40 presented with reduced LVEF (78% male, mean age 56 +/- 16 years, median LVEF 31.5% IQR 23.4-36.3%) and 209 with LVH (87% male, mean age 60 +/- 16 years, left ventricular mass 67g/m2 IQR 61-77 g/m2). 31 served as healthy controls (61% male, mean age 50 +/- 16 years, LVEF 62 +/- 5.6% and left ventricular mass 40g/m2 IQR 35-47g/m2). For detection of reduced LVEF, one parameter (QT/RR ratio) was identified with a p-value < 0.001%, AUC of 87.5%, sensitivity of 80.0%, specificity of 85.7%, and accuracy of 82.9%. For detection of LVH, the combination of three parameters (T-wave azimuth, T-wave magnitude, and azimuth variability) showed a sensitivity of 74.5%, a specificity of 68.6% and an accuracy of 73.6%. Conclusion Our study demonstrated the potential of using VCG combined with AI-based analysis as a promising screening tool for reduced LVEF and LVH. This approach may facilitate early identification of individuals who require further advanced cardiac diagnostic evaluations.central figureparameters
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Multicentre validation of an AI model for detection of reduced left ventricular ejection fractionEuropean Heart Journal · 2026
- Artificial intelligence enhanced ECG to detect reduced LVEF: clinical significance of false positive and false negative AI-ECG classificationsEuropean Heart Journal · 2026
- Prognostic power of artificial intelligence based estimation of left ventricular ejection fraction in standard and point-of-care echocardiographyEuropean Heart Journal · 2026
- Two-step screening for low EF: AI-ECG and AI-guided and interpreted handheld ultrasoundEuropean Heart Journal · 2026
- AI-ECG detection of diastolic dysfunction: A screening approach for early HFpEFEuropean Heart Journal · 2026
- Artificial Intelligence–Enhanced Electrocardiogram Models for Detection of Left Ventricular DysfunctionJACC Advances · 2026