Continuous drag ablation versus point-by-point lesion sets for pulmonary vein isolation: A systematic review and meta-analysis
S Chadha, S Rashid, E Aminov, D T Zhang
Key points
From the paper's conclusion- Compared to point-by-point, drag lesions had no difference in first pass isolation (OR 0.86, 95% CI 0.51-1.46, p=0.57) (Figure 1a), atrial arrhythmia recurrence (OR 1.18, 95% CI 0.84-1.64, p=0.34) (Figure 1b), ablation time, or complication rates (not shown).
Abstract
Background Pulmonary vein isolation (PVI) is a cornerstone of AF catheter ablation. The efficacy of continuous “drag” versus point-by-point lesion sets for PVI remains uncertain; we conducted a meta-analysis. Methods An unrestricted search of Ovid MEDLINE, Embase, and Web of Science identified studies of drag versus point-by-point ablation in PVI. The primary endpoint was first pass isolation. Secondary endpoints included atrial arrhythmia recurrence at 1 year of follow-up, procedural time, ablation time, fluoroscopy time, and procedural complication rates. Results Five studies with 714 patients (324 drag, 390 point-by-point) were included. Mean follow-up was 12.9 months, age 62.1 years, CHA2DS2-VASc score 1.6, 30.4% of patients were women, and 86.3% had paroxysmal AF. Compared to point-by-point, drag lesions had no difference in first pass isolation (OR 0.86, 95% CI 0.51-1.46, p=0.57) (Figure 1a), atrial arrhythmia recurrence (OR 1.18, 95% CI 0.84-1.64, p=0.34) (Figure 1b), ablation time, or complication rates (not shown). Drag was associated with shorter procedures (mean difference 15.9 minutes, 95% CI 11.2-20.6, p<0.001) (Figure 1c), and more fluoroscopy (mean difference 2.1 minutes, 95% CI 0.99-3.3, p<0.001) (Figure 1d). Conclusion Continuous drag lesions for PVI in AF catheter ablation showed no difference in first pass isolation or atrial arrhythmia recurrence, but yielded shorter procedures despite more fluoroscopy use, with neutral effect on ablation time and complication rates.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluation of a radiofrequency catheter ablation target based on averaged impedance drop for pulmonary vein isolationFrontiers in Cardiovascular Medicine · 2026
- Pulsed field versus conventional thermal ablation for paroxysmal atrial fibrillation: Insights from a reconstructed individual patient data meta-analysis of randomised controlled trialsEuropean Heart Journal · 2026
- Contemporary pulsed field ablation systems for atrial fibrillation: a systematic review and network meta-analysisEuropean Heart Journal · 2026
- Catheter ablation of atrial fibrillation using the pulsed-field energy; a prospective randomized comparison of the CENTAURI PEF system and the FARAPULSE SystemEuropean Heart Journal · 2026
- Pulsed field vs radiofrequency ablation for paroxysmal atrial fibrillation: the BEAT PAROX-AF trialEuropean Heart Journal · 2026
- Pulsed-field ablation demonstrates superior pulmonary vein isolation durability at 90 days: Pooled analysis of protocol-mandated remapping dataHeart Rhythm · 2025