Diagnostic yield of patient-triggered events during 14-days-electrocardiographic monitoring after transcatheter aortic valve implantation
A Bettelini, C Moser, F Jordan, J Bruegger, S Knecht, T Serban, R Stump, T Nestelberger,
Key points
From the paper's conclusion- Conclusions After TAVI, patient-triggered events during ECG patch monitoring poorly reflect objectively detected arrhythmias and substantially underestimate the burden of clinically relevant rhythm disturbances.
Abstract
Background Wearable ECG patches used after transcatheter aortic valve implantation (TAVI) enable continuous rhythm monitoring and allow patients to report symptoms via trigger buttons and diary entries. However, the correlation between triggered events and clinically relevant arrhythmias after TAVI remains uncertain. Purpose We aimed to systematically analyze patient-triggered events and their corresponding rhythm findings during 14-day ECG patch monitoring after TAVI. Methods Adult patients undergoing TAVI at a Swiss tertiary centre were prospectively enrolled and monitored with a 14-day ECG patch before discharge. Patients were instructed to record any cardiac-related symptoms using the patch trigger button and/or diary function. Results A total of 307 patients (median age 82 years [78–86], 43% female) underwent ECG patch monitoring. Median monitoring duration was 13 days [11 –14]. At least one patient-triggered event was recorded by 100 patients (33%), with a median of 2 triggered events per patient [1–5]. In 27 patients (9%) triggered events occurred exclusively during sinus rhythm without any associated arrhythmia. Atrial fibrillation was detected by continuous monitoring in 82 patients (27%), newly detected in 15 patients (5%). Among AF-patients, 22 (27%) reported symptoms during AF episodes. Pauses were identified in 59 patients (19%) and high-grade atrioventricular (AV) block in 33 patients (11%), with no triggered events during pauses and only one patient (3%) reporting associated symptoms during high-grade AV block. Ventricular tachycardia (≥3 beats) occurred in 154 patients (50%) and was not associated with any patient-triggered events. Supraventricular and ventricular ectopy (PACs, PVCs) were frequently detected and prompted patient activation in 14% and 10% of cases, respectively. On a per-event analysis 404 events were recorded. 53 (13%) were unevaluable due to imprecise diary entries. Of all symptom-reported events, 141 (35%) were not associated with any arrhythmia. The most frequent arrhythmias were PACs (89, 22%) and PVCs (77, 19%), followed by atrial fibrillation (67, 17%). Notably, 34 (8%) events were associated with more than one arrhythmia. Conclusions After TAVI, patient-triggered events during ECG patch monitoring poorly reflect objectively detected arrhythmias and substantially underestimate the burden of clinically relevant rhythm disturbances. This highlights the importance of continuous ECG monitoring after TAVI for accurate and safe arrhythmia detection in this high-risk population.Graphical Abstract
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Patient-Reported Symptoms and Arrhythmias During Continuous ECG Monitoring After Transcatheter Aortic Valve Implantation.Heart rhythm · 2026
- Time to new-onset atrial fibrillation after transaortic valve implantation using 14-days ambulatory electrocardiographic monitoringEuropean Heart Journal · 2026
- Paired 14-day ECG monitoring reveals divergent arrhythmia dynamics before and after transcatheter aortic valve implantationEuropean Heart Journal · 2026
- Silent conduction disturbances after TAVI: insights from 12-lead holter monitoringEuropean Heart Journal · 2026
- Transcatheter aortic valve implantation and need for post-discharge pacemaker implantation in the modern era of fast dischargeEuropean Heart Journal · 2026
- Potential and feasibility of wearable based long term daily ECG analysis: comparison between heart transplant recipients and healthy controlsEuropean Heart Journal · 2026