External validation, robustness, and clinical error profiling of a multimodal electrocardiogram model for structural heart disease reveals a dominant shared prediction component
G Riedemann, P Hempel, M Eberhardt, J Spauschus, J Fischer, C Schmidt, S Brandenburg, N Spicher
Key points
From the paper's conclusion- Muscle artefact was a minor threat overall, except for pericardial effusion.Figure 1- Collapse of predictions spaceFigure 2- external validation and corruption
Abstract
Background/Introduction Multitask ECG models are usually evaluated per label, but whether outputs are disease-specific or dominated by a shared component and the implications for error patterns and artefact robustness, remains unclear. Purpose To evaluate output-space structure, external validity, artefact robustness, and clinically relevant failure modes to inform emergency department (ED) deployment. Methods EchoNext Mini [1], a pretrained multimodal ECG model (12-lead ECG + 7 tabular covariates; 12 probability outputs for structural heart disease), was evaluated in (i) an internal ECG-echo cohort [2](n=10,068) and (ii) an external ED cohort [3] (n=1,000; cardiologist-adjudicated labels for LVEF≤45%, aortic stenosis, and tricuspid regurgitation). Discrimination was assessed using the area under the receiver operating characteristic curve (AUROC). Prediction-space structure was quantified by inter-output correlations and principal component analysis (PCA) and related to vectorcardiographic (VCG) morphology. Error profiles were compared. Muscle artefact robustness was tested in 1,000 internal ECGs by gradually adding high-pass filtered noise. Results Mean internal AUROC was 0.802 (range 0.734-0.866). External AUROCs were 0.769 (95% CI 0.74-0.80) for LVEF≤45%, 0.702 (0.64-0.76) for aortic stenosis, and 0.745 (0.7-0.79) for tricuspid regurgitation, corresponding to performance decrements of ΔAUROC 0.083, 0.157, and 0.088, respectively. PCA showed that PC1 explained 85.5% of prediction variance internally and 79.9% externally. Ground-truth labels were weakly correlated (median |r|=0.10), whereas predicted probabilities were strongly correlated (median |r|=0.89), suggesting a dominant shared prediction component. Externally PC1 separated disease strongly for LVEF≤45% and tricuspid regurgitation (p<1×10⁻¹⁸) but modestly for aortic stenosis (p=0.032). The QRS–T angle was the top single vectorcardiographic feature (e.g., AUROC 0.744 for LVEF≤45%; Cohen’s d=0.92). Robustness to muscle artefact was high overall (mean ΔAUROC −0.005 at 157 µV RMS), but across the 12 internal outputs pericardial effusion was most sensitive (ΔAUROC 0.159), while aortic stenosis was minimally affected (ΔAUROC 0.010). False positives were enriched in older patients with electrical remodelling (wider QRS, prolonged QTc, higher QRS-T angle), whereas false negatives clustered in younger patients with narrower QRS and lower QRS-T angle. Conclusion(s) The model generalised to external ED data with moderate, label-dependent performance loss. Multitask outputs were dominated by a shared prediction component aligned with VCG morphology, supporting broad screening/triage but limiting disease-specific inference from individual heads. Error profiling suggests likely false alarms in older remodelling phenotypes and missed disease in younger patients with minimal electrical changes. Muscle artefact was a minor threat overall, except for pericardial effusion.Figure 1- Collapse of predictions spaceFigure 2- external validation and corruption
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Multimodal ECG–language contrastive pretraining enables detection of structural heart disease from 12-Lead ECGEuropean Heart Journal · 2026
- Multimodal Transformer–Based Electrocardiogram Analysis for Cardiovascular Comorbidity Detection: Model Development and Validation StudyJMIR Formative Research · 2025
- EchoGraph-FusionNet: Adaptive Disease-Graph and Mixture-of-Experts Learning for Predicting Echocardiographic Abnormalities from ECGs.Life (Basel, Switzerland) · 2026
- Transportability of an artificial intelligence electrocardiography model for structural heart disease: external validation and recalibration of EchoNext-Mini in MIMIC-IV.European heart journal. Digital health · 2026
- Multimodal deep learning model for enhanced early detection of aortic stenosis integrating ECG and chest x-ray with cooperative learningFrontiers in Radiology · 2025
- Development and external validation of an AI- model to triage echocardiogramsEuropean Heart Journal · 2026