Transportability of an artificial intelligence electrocardiography model for structural heart disease: external validation and recalibration of EchoNext-Mini in MIMIC-IV.
Emmanuel Otabor, Abdulraheem Hassan, Ayoyimika Okunlola, Justin Lam, Laith Alomari, Michael Hamilton
Thomas Jefferson University, Philadelphia, PA 19107, USA. · Saint Peter's University Hospital, New Brunswick, NJ, USA.
Key points
From the paper's conclusion- EchoNext-Mini transported to MIMIC-IV with composite discrimination within the published external-validation range. Component probabilities behaved as ranking scores rather than absolute risks, a property of the released model rather than the validation setting, and require adjustment before use as risk estimates.
Abstract
AIMS: Structural heart disease is often underdiagnosed, and echocardiography is limited by access and referral thresholds. Artificial intelligence electrocardiography (AI-ECG) may identify echocardiographically defined structural heart disease. EchoNext-Mini is a released AI-ECG model, accompanied by a benchmark dataset, that detects a composite structural heart disease outcome and component conditions from 12-lead electrocardiogram waveforms together with age, sex, and electrocardiographic measurements. We assessed its transportability and recalibration. METHODS AND RESULTS: We linked electrocardiograms from MIMIC-IV to subsequent transthoracic echocardiograms, including adults whose electrocardiogram preceded an eligible echocardiogram within one year, one per patient. Labels were mapped to structured echocardiographic fields using original thresholds where available, harmonized definitions otherwise. The released model was applied without retraining to this cohort and its benchmark test set, then assessed for discrimination, calibration, recalibration, subgroups, and label sensitivity. Among 45 878 patients, structural heart disease prevalence was 47.2%. Composite area under the receiver operating characteristic curve was 0.790 (95% confidence interval, 0.786 to 0.794), against 0.820 on the benchmark test set. Component values ranged from 0.679 for left ventricular wall thickness to 0.837 for right ventricular dysfunction. The composite was near-calibrated (slope, 0.93), whereas all component probabilities overestimated risk in both settings. A shift derived from the released training prevalences, requiring no local outcome data, largely corrected it. CONCLUSION: EchoNext-Mini transported to MIMIC-IV with composite discrimination within the published external-validation range. Component probabilities behaved as ranking scores rather than absolute risks, a property of the released model rather than the validation setting, and require adjustment before use as risk estimates.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- EchoNext-Mini: A Dataset and Baseline AI Model for Detecting Structural Heart Disease from Electrocardiograms.NEJM AI · 2026
- Artificial intelligence-enabled electrocardiography to triage echocardiography for structural heart disease diagnosis in a low-resource settingAmerican Journal of Preventive Cardiology · 2026
- External validation, robustness, and clinical error profiling of a multimodal electrocardiogram model for structural heart disease reveals a dominant shared prediction componentEuropean Heart Journal · 2026
- Identifying Structural Heart Disease and Prioritizing Echocardiography Through Artificial Intelligence-Enabled Tele-ECG: An External Validation of the PROVAR+ Study.The American journal of cardiology · 2026
- AI-ECG Detection of Structural Heart Disease in the Community Setting: Transportability and Spectrum Effects in the PREVUE-VALVE Study.Journal of the American College of Cardiology · 2026
- TARGET-AI: A Foundational Approach for the Targeted Deployment of Artificial Intelligence Electrocardiography in the Electronic Health Record.NEJM AI · 2026