Bioadaptor versus contemporary drug-eluting stents: Meta-analysis of randomized controlled trials
O Kumet, F Saylik, R Sarikaya
Key points
From the paper's conclusion- We performed a meta-analysis of randomized controlled trials (RCTs) comparing bioadaptor devices with contemporary DES in patients undergoing PCI.
Abstract
Background Permanent metallic drug-eluting stents (DES) provide effective coronary scaffolding but may impair long-term vessel physiology due to chronic metallic caging. Bioadaptor technology has been developed to allow early mechanical support followed by adaptive vessel restoration. We performed a meta-analysis of randomized controlled trials (RCTs) comparing bioadaptor devices with contemporary DES in patients undergoing PCI. Methods A systematic meta-analysis of RCTs comparing bioadaptor versus DES was conducted. The primary endpoints were target lesion failure (TLF) and target vessel failure (TVF). Secondary endpoints included target lesion revascularization (TLR), myocardial infarction (MI), cardiovascular death, all-cause death, and definite/probable device or stent thrombosis. Risk ratios (RR) with 95% confidence intervals (CI) were pooled using a random-effects model. Heterogeneity was assessed using the I² statistic. Risk of bias was evaluated using the Cochrane RoB 2 tool. Results Three randomized controlled trials with a total of 2886 patients were included. Overall risk of bias was low in the large multicenter RCTs, with some concerns in the small mechanistic trial. Bioadaptor was associated with a numerically lower risk of target lesion failure (RR 0.70, 95% CI 0.40–1.20; I²=9.8%) and target vessel failure (RR 0.59, 95% CI 0.23–1.53; I²=64.2%) compared with DES; however, these differences did not reach statistical significance.Target lesion revascularization showed a favorable trend (RR 0.57, 95% CI 0.31–1.03; I²=0%). There were no significant differences in target-vessel myocardial infarction (RR 0.78, 95% CI 0.41–1.46; I²=0%) or any myocardial infarction (RR 1.32, 95% CI 0.79–2.22; I²=0%). Cardiovascular death (RR 0.54, 95% CI 0.06–4.66; I²=54%) and all-cause death (RR 1.36, 95% CI 0.72–2.56; I²=0%) were similar between groups. Definite or probable device/stent thrombosis was not increased with bioadaptor (RR 1.16, 95% CI 0.43–3.16; I²=0%). Conclusion In randomized evidence, bioadaptor technology demonstrates similar safety and efficacy profiles compared with contemporary DES. Although statistical significance was not reached, consistent numerical trends toward reduced lesion-related events were observed without an increased risk of thrombosis. Larger trials with extended follow-up are warranted to determine whether adaptive vessel restoration translates into meaningful long-term clinical benefit.Risk of biasFor image description, please refer to the figure legend and surrounding text.Random-Effects Meta-AnalysisFor image description, please refer to the figure legend and surrounding text.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Clinical Outcomes After Coronary Bioadaptor Versus Drug-Eluting Stent Implantation: A Systematic Review and Meta-Analysis of Randomized Controlled TrialsJournal of Personalized Medicine · 2026
- A Comprehensive Meta‐Analysis of Bioadaptor Versus Drug‐Eluting Stents in Randomised Trials With Exploratory Single‐Arm Landmark AnalysesEuropean Journal of Clinical Investigation · 2026
- Comparative Safety and Efficacy of Biodegradable and Durable Polymer Drug-Eluting Stents in Patients with Acute Coronary Syndrome: A Systematic Review and Updated Meta-Analysis.Cardiology in review · 2026
- Efficacy and Safety of Bioresorbable Vascular Scaffolds Versus Contemporary Drug-Eluting Stents in Coronary Artery Disease: A Systematic Review, Meta-Analysis, and Trial Sequential Analysis.Reviews in cardiovascular medicine · 2026
- Bioresorbable vascular scaffold versus metallic drug-eluting stent in patients at high risk of restenosis: final 7-year results of the COMPARE-ABSORB trialEuroIntervention · 2026
- Bioresorbable-polymer sirolimus-eluting stents versus durable-polymer everolimus-eluting stents in percutaneous coronary intervention: A systematic review and meta-analysis of randomized controlled trials with GRADE assessment.JRSM cardiovascular disease · 2026