科研速览 · Science Skim继续刷下去 · Keep skimming →
◆ JRSM cardiovascular disease2026-01-01

Bioresorbable-polymer sirolimus-eluting stents versus durable-polymer everolimus-eluting stents in percutaneous coronary intervention: A systematic review and meta-analysis of randomized controlled trials with GRADE assessment.

Deepanshu Agrawat, Aarushi Gupta, Munir Rajpura, Sanaa Sadikhussain Diwan, Mokshit Mehul Shah, Asma Mukhtar, Umais Naveed Warraich, Areesha Talib Lashari, Muhammad Usama Tariq, Dania Khan, Mirza Muhammad Hadeed Khawar, Muneeb Khawar

一句话结论 · In one sentence

Metallic BP-SES and DP-EES showed similar rates for most clinical endpoints. However, extreme heterogeneity and accrual of only 5.7% of the required information size render the evidence for target lesion failure inconclusive. Higher binary restenosis increased target lesion revascularisation with fully BRS indicate that these platforms are not interchangeable with contemporary metallic stents. Further large, long-term trials are required.

原始摘要(英文原文)· Original abstract
BACKGROUND: Ultrathin bioresorbable-polymer sirolimus-eluting stents (BP-SES), including bioresorbable scaffolds (BRS), were developed to mitigate adverse events associated with durable-polymer everolimus-eluting stents (DP-EES). This study aims to compare the efficacy and safety of BP-SES versus DP-EES in patients undergoing percutaneous coronary intervention for de novo coronary artery lesions. METHODS: We searched PubMed, Embase, ScienceDirect and ClinicalTrials.gov from inception to May 2026 for randomised controlled trials (RCTs) comparing BP-SES or BRS with DP-EES. Random-effects models were used to pool risk ratios (RRs) or mean differences with 95% confidence intervals (CIs). RESULTS: Nineteen RCTs involving 18,501 patients were included. No significant differences were observed between BP-SES and DP-EES for target lesion failure (RR 1.15, 95% CI 0.74-1.79; I2 = 94%), target vessel failure (RR 0.93, 95% CI 0.84-1.03; I2 = 10%), cardiac death (RR 0.96, 95% CI 0.78-1.18), target vessel myocardial infarction (RR 0.89, 95% CI 0.77-1.03), clinically indicated target lesion revascularisation (RR 0.99, 95% CI 0.80-1.22). Binary restenosis was significantly higher in the BP-SES arm overall (RR 2.46, 95% CI 1.41-4.29; p = 0.001). CONCLUSIONS: Metallic BP-SES and DP-EES showed similar rates for most clinical endpoints. However, extreme heterogeneity and accrual of only 5.7% of the required information size render the evidence for target lesion failure inconclusive. Higher binary restenosis increased target lesion revascularisation with fully BRS indicate that these platforms are not interchangeable with contemporary metallic stents. Further large, long-term trials are required.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

Bioresorbable-polymer sirolimus-eluting stents versus durable-polymer everolimus-eluting stents in percutaneous coronary intervention: A systematic review and meta-analysis of randomized controlled trials with GRADE assessment. — 科研速览 Science Skim