Machine learning CT-FFR for physiologic decision-making in diffuse coronary artery disease
Z An, Z Ma, M Zhang, L Feng, S Yang, M Zhang, C Tu, X Song,
Key points
From the paper's conclusion- These findings support CT-FFR as a practical noninvasive physiological tool to inform revascularization planning, especially when anatomy alone may underestimate ischemic burden in diffuse lesions.Correlation analysis and AUC curve
Abstract
Background Diffuse coronary artery disease (CAD) is characterized by gradual, long-segment pressure loss, which may not be fully captured by anatomy-based stenosis severity alone. Computed tomography-derived fractional flow reserve (CT-FFR) provides noninvasive physiological assessment, but its performance in diffuse disease and its relationship with treatment strategy and outcomes remain incompletely defined. Purpose To evaluate the agreement and diagnostic performance of machine learning (ML)-based CT-FFR versus invasive pressure wire-based FFR in diffuse versus non-diffuse CAD, and to explore its associations with revascularization decisions and prognosis. Methods This multicenter retrospective study included consecutive patients from 3 hospitals in China. CCTA DICOM datasets and invasive FFR data acquired within 30 days were retrospectively collected. ML-based CT-FFR was centrally computed by offline post-processing in the Keya Medical core laboratory. Diffuse disease was defined as lesion length ≥20 mm (patient-level diffuse: ≥1 diffuse vessel). Vessel-level and patient-level analyses used invasive FFR ≤0.80 as the reference standard. Treatment-decision matching (0.80 threshold) was assessed against actual management, and major adverse cardiovascular events (MACE) were analyzed using Kaplan–Meier and multivariable Cox models. Results Among 328 patients, 136 (41.5%) had diffuse CAD; 374 vessels were included for vessel-level analysis. CT-FFR showed strong correlation with invasive FFR at both vessel and patient levels (vessel: Spearman ρ=0.834, n=374, p<0.001; patient: Spearman ρ=0.828, n=328, p<0.001), with stronger correlations in diffuse than non-diffuse disease. Diagnostic discrimination was excellent overall (AUC 0.941 at both vessel and patient levels) and remained robust in diffuse CAD (patient-level AUC 0.971). Concordance between physiology-guided recommendations and actual revascularization was similar across diffuse and non-diffuse strata, with discordance predominantly driven by nonconcordant revascularization rather than nonconcordant deferral. In 208 patients with follow-up (48 MACE), Kaplan–Meier curves stratified by CT-FFR threshold did not separate significantly, and CT-FFR was not independently associated with MACE in adjusted Cox analysis (HR 1.33 per 0.10-unit change, 95% CI 0.90–1.94; p=0.15), likely reflecting attenuation of baseline physiological risk gradients by downstream revascularization. Conclusions ML-based CT-FFR closely agrees with invasive FFR and maintains strong diagnostic performance in both diffuse and non-diffuse CAD, with particularly favorable performance in diffuse disease. These findings support CT-FFR as a practical noninvasive physiological tool to inform revascularization planning, especially when anatomy alone may underestimate ischemic burden in diffuse lesions.Correlation analysis and AUC curve
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Diagnostic performance of CT-derived fractional flow reserve across coronary lesion morphologies: a prospective multicenter study.The international journal of cardiovascular imaging · 2026
- Clinical Management Across CAD-RADS Categories in Patients with Intermediate CT-FFR.Journal of cardiovascular development and disease · 2026
- Fractional Flow Reserve Measurement Using Dynamic CT Perfusion Imaging in Patients with Heavy Coronary Calcification and Stent.Diagnostics (Basel, Switzerland) · 2026
- Correlation between 15O-water PET–detected myocardial ischaemia and CT-derived FFR: Predicting the functional significance of anatomical stenosisEuropean Heart Journal · 2026
- CT-derived fractional flow reserve for anatomically long-segment coronary disease: a multicentre diagnostic accuracy study.European radiology · 2026
- Diagnostic Performance of a Novel Optical Coherence Tomography-Derived Fractional Flow Reserve: A Prospective Multicenter Study.MedComm · 2026