Outcomes of tricuspid transcatheter edge-to-edge repair and tricuspid transcatheter valve replacement for severe tricuspid regurgitation: a systematic review and meta-analysis.
Radwan Alkhatib, Taha Hatab, Osamah Badwan, Mangesh Kritya, Akiva Rosenzveig, Faysal Massad, Carl Ammoury, Chadi Tabaja,
Department of Internal Medicine, Cleveland Clinic, Cleveland, OH, USA. · Department of Cardiovascular Medicine, Heart, Vascular, and Thoracic Institute, Cleveland Clinic, Mail Code J2-3, 9500 Euclid Avenue, Cleveland, OH 44195, USA.
Key points
From the paper's conclusion- T-TEER and TTVR are associated with improvements in clinical and echocardiographic outcomes in patients with severe TR. These findings are descriptive and hypothesis-generating, highlighting the need for prospective studies to clarify optimal patient selection and long-term outcomes.
Abstract
BACKGROUND AND AIMS: Severe tricuspid regurgitation (TR) is associated with substantial morbidity, mortality, and impaired quality of life. Transcatheter tricuspid edge-to-edge repair (T-TEER) and transcatheter tricuspid valve replacement (TTVR) have emerged as treatment options, but comparative evidence to guide procedural selection remains limited. To systematically evaluate the safety and clinical outcomes of T-TEER and TTVR in patients with severe TR. METHODS AND RESULTS: A systematic review and meta-analysis were performed according to PRISMA guidelines, including studies published through July 2025. Random-effects models were used to pool outcomes at in-hospital, 30-day, and 1-year follow-up. Twenty studies comprising 4468 patients undergoing T-TEER and 20 studies including 1017 patients undergoing TTVR were included. T-TEER was associated with very low in-hospital (0.13%) and 30-day (0.46%) mortality, with 1-year mortality of 10.16%. Early mortality was high following TTVR, whereas 1-year mortality was similar between strategies. TTVR achieved more complete and durable elimination of severe TR, while T-TEER resulted in meaningful but less complete TR reduction. Both approaches were associated with substantial improvements in New York Heart Association functional class and quality of life. TTVR was associated with higher rates of permanent pacemaker implantation, thrombotic events, and major bleeding that increased over time, whereas bleeding after T-TEER was predominantly peri-procedural. Changes in right ventricular systolic function were modest and similar between approaches. CONCLUSION: T-TEER and TTVR are associated with improvements in clinical and echocardiographic outcomes in patients with severe TR. These findings are descriptive and hypothesis-generating, highlighting the need for prospective studies to clarify optimal patient selection and long-term outcomes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Transcatheter Tricuspid Edge-To-Edge Repair Versus Transcatheter Tricuspid Valve Replacement for Severe Symptomatic Tricuspid Regurgitation.JACC. Cardiovascular interventions · 2026
- Transcatheter Tricuspid Valve Replacement Versus Medical Therapy for Severe Secondary Tricuspid Regurgitation: The TRIPLACE Registry.JACC. Cardiovascular interventions · 2026
- Post-repair transcatheter tricuspid valve replacement for severe tricuspid regurgitationEuropean Heart Journal · 2026
- Transcatheter tricuspid valve replacement for severe tricuspid regurgitation: current and future perspectives.Expert review of medical devices · 2026
- Transcatheter tricuspid valve replacement-a comparison of clinical and procedural outcomes of two different prostheses.Frontiers in cardiovascular medicine · 2026
- Transcatheter tricuspid valve replacement after failed edge-to-edge repair.EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2026