From the paper's conclusion
  • Despite more complete TR reduction, orthotopic TTVR may be associated with earlier all-cause mortality and MACE penalty over T-TEER. This hypothesis-generating analysis should spur further research to identify the optimal patient phenotype for T-TEER and TTVR technologies.

Abstract

BACKGROUND: Transcatheter tricuspid edge-to-edge repair (T-TEER) and transcatheter tricuspid valve replacement (TTVR) are both approved for severe symptomatic tricuspid regurgitation (TR) but lack head-to-head comparison. OBJECTIVES: This study sought to compare 1-year outcomes of T-TEER vs TTVR using causal inference in a harmonized real-world cohort. METHODS: TRIVALVE (International Multisite Transcatheter Tricuspid Valve Therapies Registry) (T-TEER, n = 384) and TRIPLACE (Global Multicenter Registry on Transcatheter TRIcuspid Valve RePLACEment) (TTVR, n = 398) registries were harmonized (n = 782). Inverse probability weighted survival time estimated study group average treatment effect (ATE) and treated-study group average treatment effect on the treated (ATET) effects on time to all-cause death, heart failure hospitalization (HFH), tricuspid valve (TV) reintervention, bleeding, and their composite major adverse cardiovascular events (MACE), balanced for 14 baseline clinical/echocardiographic covariates, were undertaken. RESULTS: Median follow-up by reverse Kaplan-Meier estimates was 276 days (IQR: 58-365). TTVR achieved near-complete TR elimination vs persistent mild-moderate residual TR post-T-TEER [median (IQR) grade 0 (0-1) vs 2 (1-2)]. Modeling demonstrated an early all-cause mortality penalty for TTVR (ATE: -81.3 days, P = 0.002; ATET: -79 days, P = 0.003) with a corresponding overall MACE signal (ATE: -70.7 days, P = 0.001; ATET: -69.3 days, P = 0.012). CONCLUSIONS: Despite more complete TR reduction, orthotopic TTVR may be associated with earlier all-cause mortality and MACE penalty over T-TEER. This hypothesis-generating analysis should spur further research to identify the optimal patient phenotype for T-TEER and TTVR technologies.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers