Volume-outcome analysis of in-hospital complications after cardiac implantable electronic device implantation: a 250 000-case study‡.
Paulina Vitkauskė, Maurilio Gutzeit, Heike Jaegers, Heinz-Jürgen Adomeit, Susanne Macher-Heidrich, Fuad Hasan, Markus Zarse, Harilaos Bogossian,
Medical Faculty, Ruhr University Bochum, Universitätsstraße 150, Bochum 44801, Germany. · IU International University of Applied Sciences, Juri-Gagarin-Ring 152, Erfurt 99084, Germany.
Key points
From the paper's conclusion- This study demonstrates a statistically significant association between implantation volume and complication rates across all CIED procedures, with the effect being particularly pronounced among pacemaker patients.
Abstract
AIMS: Although implantation volume of cardiac implantable electronic device (CIED) is widely considered a prognostic factor, Germany continues to show a wide distribution of hospitals performing CIED procedures, with annual volumes ranging from fewer than 10 to over 500 cases. Using a new statistical volume-outcome model, we examined the existence and shape of the relationship between complication rates and hospital volume. METHODS AND RESULTS: The analysis is based on data from all first inpatient CIED implantations performed between 1 January 2010 and 31 December 2020, in hospitals across North Rhine-Westphalia. All peri- and post-operative complications documented in mandatory quality assurance were included. A possible association between implantation volume and quality was assessed using a flexible generalized additive mixed model. Out of 249 118 cases, the overall complication rate was 2.4%, with lead-related issues being the most common (1.5%). Forest plot analysis identified American Society of Anaesthesiologists Class 4-5, New York Heart Association Class IV, subclavian vein access, and dual-chamber pacemaker systems as the strongest predictors of complications. Volume-outcome analysis revealed a significant association between implantation volume and complications, particularly among pacemaker patients [P < 0.001, area under the curve (AUC) 0.7], and showed a relevant reduction in hospital stays and healthcare costs. Modelling suggested that a 50-case annual cut-off could prevent ∼16% of complications, requiring ∼16% of patients to be redirected to other hospitals. CONCLUSION: This study demonstrates a statistically significant association between implantation volume and complication rates across all CIED procedures, with the effect being particularly pronounced among pacemaker patients.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Hospital costs associated with early complications following cardiovascular implantable electronic device implantation: a retrospective cohort study*BMC Health Services Research · 2026
- Trends in cardiac implantable electronic device infections: 2015 to 2019BMC Cardiovascular Disorders · 2026
- Sex-based disparities in early complications following cardiac implantable electronic device implantation: a nationwide analysisEuropean Heart Journal · 2026
- Complication rates of cardiac implantable electronic device implantation in cardiac surgery patientsEuropean Heart Journal · 2026
- Predicting Major Adverse Events With Cardiac Resynchronization, Leadless, and Conduction System Pacemaker Implantation.Pacing and clinical electrophysiology : PACE · 2026
- An urgent call for quality measures for cardiac implantable electronic device infections in the United States.American heart journal plus : cardiology research and practice · 2026