European heart journal open

Polymer-free amphilimus-eluting stents vs. biodegradable-polymer everolimus stents for PCI: 2-year results of the PARTHENOPE trial.

Raffaele Piccolo, Angelo Laino, Greta Carrara, Paolo Calabrò, Fiorenzo Simonetti, Attilio Varricchio, Tiziana Attisano, Giovanni Napolitano,

Department of Advanced Biomedical Sciences, University of Naples 'Federico II', Via Sergio Pansini, 5, 80131 Naples, Italy. · Advice Pharma Group, Via Giovanni Durando, 38, 20158 Milan, Italy.

Trial · n=2,107

Key points

From the paper's conclusion
  • In patients undergoing PCI, PF-AES yielded similar outcomes compared to BP-EES at 2-years. The late benefit with PF-AES warrants further investigation.

Abstract

AIMS: Drug-eluting stents are the standard of care for percutaneous coronary intervention (PCI), yet long-term evidence on polymer-free stents remains limited. The aim of this study was to evaluate the clinical outcomes associated with polymer-free amphilimus-eluting stent (PF-AES) compared with biodegradable polymer everolimus-eluting stent (BP-EES) in patients undergoing PCI at 2 years of follow-up. METHODS AND RESULTS: We conducted a randomized, investigator-initiated, assessor-blind, noninferiority trial with minimal exclusion criteria at 14 centres. Patients undergoing PCI were randomized to PF-AES vs. BP-EES. The primary endpoint was a device-oriented composite endpoint (DOCE) of cardiovascular death, target-vessel myocardial infarction, or target-lesion revascularization. We included 2107 patients with 3042 coronary lesions. At 2-years, DOCE occurred at similar rates between patients randomized to PF-AES vs. BP-EES [10.1% vs. 10.6%, hazard ratio (HR) 0.96, 95% confidence intervals (CIs) 0.73-1.25, P = 0.74]. Rates of individual DOCE components were comparable, including cardiovascular death (4.2% vs. 3.9%), target-vessel myocardial infarction (5.2% vs. 5.6%), and clinically driven target-lesion revascularization (2.3% vs. 2.6%). Landmark analysis showed a significant interaction between randomized stent and follow-up period (P-interaction = 0.025). While DOCE rates were similar from 0 to 1 year (8.2% vs. 7.2%; HR 1.15, 95%CI 0.84-1.56), PF-AES was associated with a lower risk of DOCE between 1 and 2 years compared with BP-EES (2.1% vs. 3.7%; HR 0.56, 95%CI 0.32-0.96). CONCLUSION: In patients undergoing PCI, PF-AES yielded similar outcomes compared to BP-EES at 2-years. The late benefit with PF-AES warrants further investigation. CLINICAL TRIAL REGISTRATION: NCT04135989.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers