A framework for increasing scanner efficiency: the utility of a 'Short aorta' protocol to increase cardiac MRI capacity at the Yorkshire Heart Centre.
Henry Procter, Jun Hui Tan, Lizette Cash, Marilena Giannoudi, Sindhoora Kotha, Sven Plein, Ananth Kidambi, Eylem Levelt,
Department of Cardiology, Leeds Teaching Hospitals NHS Trust, Great George Street, Leeds LS1 3EX, United Kingdom. · Department of Cardiometabolic Imaging, Baker Heart and Diabetes Institute, Melbourne, Australia.
Key points
From the paper's conclusion- This project retrospectively analysed clinical and scan characteristics of patients referred to the Yorkshire Heart Centre for CMR before and after introduction of a ‘Short aorta’ protocol.
Abstract
There are rising demands for cardiovascular magnetic resonance imaging (CMR) worldwide. Thoracic aorta assessment is a common CMR indication. There are many benefits to shorter scan times including improved patient experience, as well as efficiency of a service. This service development project aimed to optimize the current 'aorta' protocol in a large tertiary CMR centre in the United Kingdom (which includes aortic valve [AV] and left ventricle [LV] assessment), with the aim to reduce scanning and reporting times. A 'Short aorta' protocol was devised (where only the thoracic aorta is assessed). The 'Short aorta' protocol requires a 30-minute scan slot, whereas the 'Full aorta' protocol (assessing thoracic aorta, AV and LV function) requires 60 minutes. This project retrospectively analysed clinical and scan characteristics of patients referred to the Yorkshire Heart Centre for CMR before and after introduction of a 'Short aorta' protocol. Over the two 13-week audit periods, thoracic aorta assessment was the main indication for 137 CMR referrals. Based on clinical indication, 95 (69%) could have used the 'Short aorta' protocol. After introduction of the 'Short aorta' protocol, 39 (46%) of 85 scans were protocolled as 'Short aorta'. This resulted in significantly reduced scan times compared to the original 'aorta' protocol: 18 (IQR 15, 21) vs. 37 (IQR 32, 42) minutes; P = <0.0001). Over the second audit period, 1.2 h of scanner time per week was saved. With appropriate protocolling and booking, 1.9 h of scanner time could be saved. This is significant capacity which can improve waiting times, offering better service for patients.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Improving Cardiac Magnetic Resonance Scanning Efficiency: Impact on Diagnostic Image Quality and Patient Management.JACC. Case reports · 2026
- Personalized Cine Cardiac MRI Protocol Optimization Using a Retrieval-Augmented Large Language Model: A Prospective Comparison With Technologist-Optimized Protocol.Journal of magnetic resonance imaging : JMRI · 2026
- Left Ventricular Volume and Function Assessment Using a Reduced-Slice Approach in Cardiovascular Magnetic ResonancemedRxiv · 2026
- Impact Benchmark: Peer-to-Peer Quality-Improvement Program to Optimize Transcatheter Aortic Valve Implantation Processes and Resources.CJC open · 2026
- Reducing General Anesthesia Use in Pediatric Cardiac Magnetic Resonance Imaging.Pediatric quality & safety · 2026
- Preoperative anaesthetic and cardiology MDT: Enhancing perioperative efficiency in elective non-cardiac surgery.Journal of perioperative practice · 2026