Personalized Cine Cardiac MRI Protocol Optimization Using a Retrieval-Augmented Large Language Model: A Prospective Comparison With Technologist-Optimized Protocol.
Sadegh Dehghani, Ali Farashahi, Ibtihal Raheem Hammood
Radiation Sciences Department, School of Allied Medical Sciences, Tehran University of Medical Sciences, Tehran, Iran. · Tehran Heart Center, Tehran University of Medical Sciences, Tehran, Iran.
Key points
From the paper's conclusion- Compared to technologist-, AI-optimized cine protocols demonstrated significantly higher image quality (3.69 ± 0.47 vs. 3.00 ± 0.49, p < 0.001) and artifact suppression (3.19 ± 0.35 vs. 2.17 ± 0.45, p < 0.001). The AI-optimized protocol reduced repeat acquisitions by 68% (6 vs. 19 repeats, p = 0.028). No significant differences were observed in LV functional parameters between both protocols (all p > 0.05). Bland-Altman analysis showed minimal bias for all LV functional parameters.
Abstract
BACKGROUND: Cine cardiac magnetic resonance imaging (MRI) protocols are typically based on static templates, which may not optimally address individual patient limitations such as arrhythmia or limited breath-hold capacity. PURPOSE: To test whether an artificial intelligence (AI) framework using a large language model with retrieval-augmented generation (LLM-RAG) can provide cine cardiac MRI protocols that are equivalent or noninferior to those of technologist-optimized protocols. STUDY TYPE: Prospective, intra-individual comparative, nonrandomized. POPULATION/SUBJECTS: Sixty-eight patients (mean age 46 ± 18 years; 39 women) referred for clinical cardiac MRI, including patients with normal function as well as those with arrhythmia, implants, or limited breath-hold capacity. FIELD STRENGTH/SEQUENCE: 1.5 T, cine cardiac MRI. ASSESSMENT: Each participant underwent cine cardiac MRI twice in one session. First with a technologist-optimized protocol, then with an AI-optimized protocol (fixed order). Image quality and artifact suppression were assessed using four-point Likert scales by two blinded readers. Left ventricular (LV) functional parameters and repeat acquisitions were recorded. STATISTICAL TESTS: Wilcoxon signed-rank test, McNemar's test, paired t-tests, and Bland-Altman analysis. Significance set at p < 0.05. RESULTS: Compared to technologist-, AI-optimized cine protocols demonstrated significantly higher image quality (3.69 ± 0.47 vs. 3.00 ± 0.49, p < 0.001) and artifact suppression (3.19 ± 0.35 vs. 2.17 ± 0.45, p < 0.001). The AI-optimized protocol reduced repeat acquisitions by 68% (6 vs. 19 repeats, p = 0.028). No significant differences were observed in LV functional parameters between both protocols (all p > 0.05). Bland-Altman analysis showed minimal bias for all LV functional parameters. DATA CONCLUSION: In this nonrandomized study, a LLM-RAG framework generated cine cardiac MRI protocols that were noninferior to technologist-optimized protocols for image quality and demonstrated high agreement for LV functional measurements with fewer repeat acquisitions. These findings demonstrated the feasibility of AI-guided patient-adaptive protocoling. Randomized trials are warranted. EVIDENCE LEVEL: 2. TECHNICAL EFFICACY: Stage 2.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Reliability of Gemini 2.5 Pro, ChatGPT 4.1, DeepSeek V3, and Claude Opus 4 in generating standardized CMR protocolsEuropean Radiology Experimental · 2026
- The Current Status of AI-accelerated MRI Techniques in Clinical UseRadiology · 2025
- Impact of Documentation Aids on the Inclusion of Salient Left-Ventricular Late Gadolinium Enhancement Characteristics in Cardiac Magnetic Resonance Imaging Impressions.Journal of imaging informatics in medicine · 2026
- Large Language Models in Cardiovascular Imaging: Current Applications and Future ProspectsMed Research · 2025
- International Survey of Advanced Cardiovascular Magnetic Resonance Capabilities, Electrophysiology Applications, and Multicenter ReadinessJournal of Clinical Medicine · 2026
- Deep learning reconstruction for fast cardiovascular magnetic resonance imaging protocol: A comparative study with conventional cardiovascular magnetic resonanceJournal of Cardiovascular Magnetic Resonance · 2025