Enhancing Cone-Beam Computed Tomography Image Quality Using Deep Learning-based Super-Resolution.
Hossein Mohammad-Rahimi, Ali Nosrat, Lars Schropp, Jennifer Christensen, Matheus Sampaio-Oliveira, Rubens Spin-Neto, Ruben Pauwels
Department of Dentistry and Oral Health, Aarhus University, Vennelyst Boulevard 9, 8000 Aarhus C, Denmark. · Division of Endodontics, Department of Advanced Oral Sciences and Therapeutics, School of Dentistry, University of Maryland, Baltimore, 650 West Baltimore Street, Baltimore, MD 21201, USA.
Key points
From the paper's conclusion- Transformer-based SR improved the perceived quality of clinical CBCT images. HAT and DRCT trained with L1 pixel loss alone, and DRCT trained with L1 and edge loss, demonstrated superior performance.
Abstract
OBJECTIVES: To develop deep learning super-resolution (SR) models for enhancing cone-beam computed tomography (CBCT). METHODS: Seventy CBCT volumes (75 µm voxel size) served as references. Paired low-resolution (LR) volumes (300 µm) were simulated using physics-based degradation. Four architectures were each trained with three loss configurations (L1; L1+edge; L1+edge+perceptual): Swin Transformer for Image Restoration (SwinIR), Hybrid Attention Transformer (HAT), Hybrid Multi-Axis Aggregation Network (HMA-Net), and Dense-Residual-Connected Transformer (DRCT). Performance was assessed with peak signal-to-noise ratio (PSNR), structural similarity index measure (SSIM), learned perceptual image patch similarity (LPIPS), and deep image structure and texture similarity (DISTS). Three dentists ranked the 12 configurations in 28 sets using blinded forced-choice pairwise comparisons. Correlations of metrics and expert ranks were assessed using Spearman correlation. RESULTS: All configurations outperformed LR input and bicubic interpolation on every metric (p < 0.05). HMA-Net trained with L1+edge+perceptual loss performed best on LPIPS (0.216) and DISTS (0.186). HAT with L1 loss achieved the highest PSNR (28.79 dB) and SSIM (0.820). Experts ranked DRCT and HAT with L1 loss, and DRCT with L1+edge loss, as the best configurations (p < 0.001 versus others). Expert rank correlated moderately only with PSNR (rho = -0.65) and SSIM (rho = -0.60; both p < 0.05). CONCLUSIONS: Transformer-based SR improved the perceived quality of clinical CBCT images. HAT and DRCT trained with L1 pixel loss alone, and DRCT trained with L1 and edge loss, demonstrated superior performance. ADVANCES IN KNOWLEDGE: Transformer-based super-resolution improved expert-perceived detail of simulated low-resolution in vivo CBCT scans without additional radiation dose, supporting further validation on directly acquired low-resolution scans.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- HARU-Net: Hybrid Attention Residual U-Net for Edge-Preserving Denoising in Cone-Beam Computed Tomography.Biomedical physics & engineering express · 2026
- Evaluation of Maxillary Sinus Membrane Morphology Using a Novel Hybrid CNN-ViT-Based Deep Learning Model: An Automated Classification StudyDiagnostics · 2026
- Conditional diffusion models for high-fidelity synthetic CT generation from CBCT in nasopharyngeal carcinoma adaptive radiotherapy: a multi-center study.Physics in medicine and biology · 2026
- Deep Learning Super-Resolution CT Versus Ultra-High-Resolution CT: A Direct Comparison in Cadaveric Human Lungs.Academic radiology · 2026
- Trans2-CBCT: A Dual-Transformer Framework for Sparse-View CBCT Reconstruction.Sensors (Basel, Switzerland) · 2026
- Reliability-weighted patch learning for synthetic CT reconstruction in head and neck adaptive radiotherapy: A proof-of-concept study.Medical physics · 2026