Dento maxillo facial radiology

Enhancing Cone-Beam Computed Tomography Image Quality Using Deep Learning-based Super-Resolution.

Hossein Mohammad-Rahimi, Ali Nosrat, Lars Schropp, Jennifer Christensen, Matheus Sampaio-Oliveira, Rubens Spin-Neto, Ruben Pauwels

Department of Dentistry and Oral Health, Aarhus University, Vennelyst Boulevard 9, 8000 Aarhus C, Denmark. · Division of Endodontics, Department of Advanced Oral Sciences and Therapeutics, School of Dentistry, University of Maryland, Baltimore, 650 West Baltimore Street, Baltimore, MD 21201, USA.

Computational

Key points

From the paper's conclusion
  • Transformer-based SR improved the perceived quality of clinical CBCT images. HAT and DRCT trained with L1 pixel loss alone, and DRCT trained with L1 and edge loss, demonstrated superior performance.

Abstract

OBJECTIVES: To develop deep learning super-resolution (SR) models for enhancing cone-beam computed tomography (CBCT). METHODS: Seventy CBCT volumes (75 µm voxel size) served as references. Paired low-resolution (LR) volumes (300 µm) were simulated using physics-based degradation. Four architectures were each trained with three loss configurations (L1; L1+edge; L1+edge+perceptual): Swin Transformer for Image Restoration (SwinIR), Hybrid Attention Transformer (HAT), Hybrid Multi-Axis Aggregation Network (HMA-Net), and Dense-Residual-Connected Transformer (DRCT). Performance was assessed with peak signal-to-noise ratio (PSNR), structural similarity index measure (SSIM), learned perceptual image patch similarity (LPIPS), and deep image structure and texture similarity (DISTS). Three dentists ranked the 12 configurations in 28 sets using blinded forced-choice pairwise comparisons. Correlations of metrics and expert ranks were assessed using Spearman correlation. RESULTS: All configurations outperformed LR input and bicubic interpolation on every metric (p < 0.05). HMA-Net trained with L1+edge+perceptual loss performed best on LPIPS (0.216) and DISTS (0.186). HAT with L1 loss achieved the highest PSNR (28.79 dB) and SSIM (0.820). Experts ranked DRCT and HAT with L1 loss, and DRCT with L1+edge loss, as the best configurations (p < 0.001 versus others). Expert rank correlated moderately only with PSNR (rho = -0.65) and SSIM (rho = -0.60; both p < 0.05). CONCLUSIONS: Transformer-based SR improved the perceived quality of clinical CBCT images. HAT and DRCT trained with L1 pixel loss alone, and DRCT trained with L1 and edge loss, demonstrated superior performance. ADVANCES IN KNOWLEDGE: Transformer-based super-resolution improved expert-perceived detail of simulated low-resolution in vivo CBCT scans without additional radiation dose, supporting further validation on directly acquired low-resolution scans.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Enhancing Cone-Beam Computed Tomography Image Quality Using Deep Learning-based Super-Resolution — Science Skim