Reliability-weighted patch learning for synthetic CT reconstruction in head and neck adaptive radiotherapy: A proof-of-concept study.
Jeong Heon Kim, Sven Olberg, Byong Su Choi, Sridhar Yaddanapudi, Xiaoying Liang, Bo Lu, Jun Tan, Jin Sung Kim,
Department of Radiation Oncology, Mayo Clinic, Jacksonville, Florida, USA. · Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, New York, USA.
Key points
From the paper's conclusion- HQ-PatchNet provides a computationally efficient and clinically promising approach for daily CBCT-guided online ART by improving CBCT-to-sCT image quality while maintaining rapid inference speed. Further contour-based, multi-institutional, and multi-site validation remains necessary to confirm its broader clinical utility.
Abstract
BACKGROUND: Cone-beam computed tomography (CBCT) is essential for adaptive radiotherapy (ART) but is limited by poor image quality. Existing deep learning methods for synthetic CT (sCT) generation face a critical trade-off: diffusion models offer high fidelity but are impractically slow, while fast-inference networks often lack structural accuracy and optimization stability. PURPOSE: To develop HQ-PatchNet, a reliability-driven deep learning framework designed to improve CBCT-to-sCT image quality while maintaining rapid inference speed for online ART workflows. METHODS: HQ-PatchNet utilizes a vision transformer (ViT)-integrated CycleGAN architecture. It introduces a reliability-driven, SSIM-based selective patch weighting mechanism controlled by a temperature decay schedule. This dynamically suppresses artifact-dominated regions and focuses optimization on anatomically reliable structures. The model was evaluated on 304 paired head-and-neck (HN) scans against conventional networks and recent diffusion models using quantitative metrics (MAE, SSIM, NCC, PSNR), computational speed, and clinical dosimetric accuracy (3D gamma index, 2%/2 mm). RESULTS: HQ-PatchNet improved image quality, reducing Mean Absolute Error (MAE) from 44.81 ± 11.24 HU to 11.85 ± 4.31 HU and achieving an SSIM of 0.960 ± 0.055, comparable to state-of-the-art diffusion models. Inference required only 6.42 ± 1.71 s per volume, compared to > 15 min for diffusion approaches. The model reduced severe metal and truncation artifacts, and representative qualitative assessment suggested visually consistent sCT generation under interfractional anatomical variation. Dosimetric assessment of complex HN IMRT plans yielded a high average gamma passing rate of 99.32 ± 0.56%. CONCLUSIONS: HQ-PatchNet provides a computationally efficient and clinically promising approach for daily CBCT-guided online ART by improving CBCT-to-sCT image quality while maintaining rapid inference speed. Further contour-based, multi-institutional, and multi-site validation remains necessary to confirm its broader clinical utility.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Conditional diffusion models for high-fidelity synthetic CT generation from CBCT in nasopharyngeal carcinoma adaptive radiotherapy: a multi-center study.Physics in medicine and biology · 2026
- Knowledge‐distilled diffusion models for improving cone‐beam CT image quality with meta‐learning under imbalanced dataMedical Physics · 2026
- Fidelity-oriented pelvic CBCT-to-CT synthesis using an anatomical information-attention diffusion model.Physical and engineering sciences in medicine · 2026
- TransNSNet: A Transformer-Enhanced Multi-Scale Adversarial Framework for CT-to-PET Image SynthesisarXiv · 2026
- Accelerating Variational Cone-Beam CT Reconstruction with Learned Warm StartsarXiv · 2026
- Prior-refined Segment Anything Model enables quality-robust liver segmentation on cone-beam CT for adaptive radiotherapyScientific Reports · 2026