Imaging of the inferior alveolar nerve using dental-dedicated MRI at 0.55 T: Comparison of a deep learning-based accelerated sequence with a conventional sequence.
Maximilian Hinsen, Markus Kopp, Martin Zeilinger, Claudius S Mathy, Michael Uder, Andreas Greiser, Manuel Weber, Ines Willershausen,
Institute of Radiology, University Hospital of Erlangen, Friedrich-Alexander University Erlangen-Nuremberg, Erlangen, Germany. · Siemens Healthineers AG, Erlangen, Germany.
Key points
From the paper's conclusion- This study demonstrates that a DL-accelerated T1-weighted gradient-echo 3D sequence for dental-dedicated MRI is feasible for imaging of the IAN with improved image quality while reducing acquisition time by 50%.
Abstract
OBJECTIVES: The aim of this study was to investigate the feasibility of low-field dental MRI in the evaluation of the inferior alveolar nerve (IAN) and the acceleration of image acquisition with a deep learning (DL)-based sequence. Therefore, overall image quality (OIQ), image artefacts and delineation of the IAN were investigated. METHODS: In this single-centre retrospective study, we enrolled 39 patients who underwent dental MRI using a dedicated dental coil on a 0.55 T MRI system. A conventional T1-weighted gradient-echo 3D sequence and a T1-weighted gradient-echo 3D sequence with advanced DL-based reconstruction were acquired. Both sequences were evaluated for OIQ, image artefacts in and conspicuity of the IAN using a Likert scale from 1 to 5. Interrater agreement was assessed using weighted Cohen's κ coefficients. As quantitative measurements, the apparent signal-to-noise ratio (aSNR) and the diameter of the IAN were determined. RESULTS: Thirty-three examinations were included, OIQ was rated higher for the accelerated sequence compared with the conventional sequence for both readers (p < 0.01). Image artefacts were lower in the accelerated sequence for both readers (p < 0.001). Accordingly, the delineation of the IAN was improved for both sides (p < 0.001) in the accelerated sequence. Interrater agreement between readers was substantial/good to almost perfect/excellent across all measures. aSNR was increased in the accelerated sequence (p < 0.001), whereas IAN diameter did not differ. CONCLUSIONS: This study demonstrates that a DL-accelerated T1-weighted gradient-echo 3D sequence for dental-dedicated MRI is feasible for imaging of the IAN with improved image quality while reducing acquisition time by 50%. ADVANCES IN KNOWLEDGE: Reduction of scan time and superior image quality could help establish dental-dedicated MRI as a radiation-free alternative for dentomaxillofacial imaging.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Visualizing the inferior alveolar nerve in magnetic resonance images: a systematic review of different sequences.Odontology · 2026
- Diagnostic efficacy of deep learning-based denoising of low-field 0.55 T compared to conventional 3 T knee MRI.European journal of radiology · 2026
- Evaluation of Intracranial Lesions Using Deep Learning‐Based Reconstruction in Canine Brain MRI: Comparison With Conventional Reconstruction on T2‐Weighted and FLAIR SequencesVeterinary Radiology & Ultrasound · 2026
- Optimizing 3D FLAIR imaging of endolymphatic hydrops: Benefits and limitations of deep learning reconstruction.Diagnostic and interventional imaging · 2026
- Practical application of 0.55T dental-dedicated MRI in dentistry and maxillofacial surgery.Oral surgery, oral medicine, oral pathology and oral radiology · 2026
- Accelerated Multi-Shot Diffusion-Weighted MRI of the Head and Neck Using Deep Learning Reconstruction.Clinical neuroradiology · 2026