Dento maxillo facial radiology

Imaging of the inferior alveolar nerve using dental-dedicated MRI at 0.55 T: Comparison of a deep learning-based accelerated sequence with a conventional sequence.

Maximilian Hinsen, Markus Kopp, Martin Zeilinger, Claudius S Mathy, Michael Uder, Andreas Greiser, Manuel Weber, Ines Willershausen,

Institute of Radiology, University Hospital of Erlangen, Friedrich-Alexander University Erlangen-Nuremberg, Erlangen, Germany. · Siemens Healthineers AG, Erlangen, Germany.

Computational · n=39

Key points

From the paper's conclusion
  • This study demonstrates that a DL-accelerated T1-weighted gradient-echo 3D sequence for dental-dedicated MRI is feasible for imaging of the IAN with improved image quality while reducing acquisition time by 50%.

Abstract

OBJECTIVES: The aim of this study was to investigate the feasibility of low-field dental MRI in the evaluation of the inferior alveolar nerve (IAN) and the acceleration of image acquisition with a deep learning (DL)-based sequence. Therefore, overall image quality (OIQ), image artefacts and delineation of the IAN were investigated. METHODS: In this single-centre retrospective study, we enrolled 39 patients who underwent dental MRI using a dedicated dental coil on a 0.55 T MRI system. A conventional T1-weighted gradient-echo 3D sequence and a T1-weighted gradient-echo 3D sequence with advanced DL-based reconstruction were acquired. Both sequences were evaluated for OIQ, image artefacts in and conspicuity of the IAN using a Likert scale from 1 to 5. Interrater agreement was assessed using weighted Cohen's κ coefficients. As quantitative measurements, the apparent signal-to-noise ratio (aSNR) and the diameter of the IAN were determined. RESULTS: Thirty-three examinations were included, OIQ was rated higher for the accelerated sequence compared with the conventional sequence for both readers (p < 0.01). Image artefacts were lower in the accelerated sequence for both readers (p < 0.001). Accordingly, the delineation of the IAN was improved for both sides (p < 0.001) in the accelerated sequence. Interrater agreement between readers was substantial/good to almost perfect/excellent across all measures. aSNR was increased in the accelerated sequence (p < 0.001), whereas IAN diameter did not differ. CONCLUSIONS: This study demonstrates that a DL-accelerated T1-weighted gradient-echo 3D sequence for dental-dedicated MRI is feasible for imaging of the IAN with improved image quality while reducing acquisition time by 50%. ADVANCES IN KNOWLEDGE: Reduction of scan time and superior image quality could help establish dental-dedicated MRI as a radiation-free alternative for dentomaxillofacial imaging.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Imaging of the inferior alveolar nerve using dental-dedicated MRI at 0.55 T: Comparison of a deep learning-based accelerated sequence with a conventional sequence — Science Skim