Odontology

Visualizing the inferior alveolar nerve in magnetic resonance images: a systematic review of different sequences.

Parisa Soltani, Amirhossein Moaddabi, Aida Ekhtiari, Nasim Razavi, Amirali Gilani, Kosar Rafiei, Maryam Rasekhi, Mahsa Moannaei,

Department of Neurosciences, Reproductive and Odontostomatological Sciences, University of Naples "Federico II", Naples, Italy. · Department of Oral and Maxillofacial Surgery, Dental Research Center, School of Dentistry, Mazandaran University of Medical Sciences, Sari, Iran.

Review

Key points

From the paper's conclusion
  • In conclusion, MRI sequences, particularly DESS, STIR, and other optimized high-resolution protocols, demonstrate promising performance for IAN visualization and delineation.

Abstract

This systematic review aimed to evaluate the visualization and delineation performance of different magnetic resonance imaging (MRI) sequences for inferior alveolar nerve (IAN), focusing on detectability, image quality, and observer agreement. Following PRISMA 2020 guidelines, a comprehensive search was conducted in PubMed/MEDLINE, EMBASE, Scopus, Web of Science, and Cochrane Library for studies published until 1 March 2025. Eligible studies assessed MRI sequences for IAN visualization in adults. Risk of bias was evaluated using the Joanna Briggs Institute checklist. Twenty-five studies (1998-2024) were included, with sample sizes ranging from 5 to 85 participants. Most of these studies had a low risk of bias. MRI achieved high visualization performance of the IAN, often exceeding 90%. Advanced sequences such as DESS, STIR, SPACE STIR, CISS, and fat-suppressed protocols provided promising results in visualizing continuity and tissue contrast compared to conventional imaging and CBCT within individual studies. Diffusion-based imaging enabled tractography with reproducibility up to ICC 0.97. Novel approaches including PETRA UTE, zero-TE MRI, and MR orthopantomograms allowed radiographic-like bone visualization without radiation. VIBE sequence performed well but was more susceptible to artifacts, while SPACE STIR required longer acquisition times. In conclusion, MRI sequences, particularly DESS, STIR, and other optimized high-resolution protocols, demonstrate promising performance for IAN visualization and delineation. However, the heterogeneity of outcome measures and the limited availability of independent reference standards preclude definitive conclusions regarding diagnostic accuracy. Further studies using appropriate reference standards and clinically representative populations are needed to establish the diagnostic value of MRI for preoperative assessment.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers