B-408 Evaluation of the infliximab and adalimumab therapeutic drug monitoring tests from ProciseDx in a pediatric setting

Adam Ptolemy, Alexander Kolb, Veda Browne, Roy Peake, Mark Kellogg

Key points

From the paper's conclusion
  • The FDA-clearance, significantly improved turnaround time, and accuracy of these tests make the ProciseDx system an attractive alternative platform for routine pediatric TDM of IFX and ADL.

Abstract

Background Reactive and proactive therapeutic drug monitoring (TDM) of the biological therapies infliximab (IFX) and adalimumab (ADL) are effective tools for managing patients with inflammatory bowel disease (IBD). The Procise IFX and ADL serum assays on the benchtop ProciseDx instrument are FDA-cleared and deploy time-resolved fluorescence resonance energy transfer (TR-FRET) technology to provide rapid (<5 min) testing that is amendable to near-patient settings. We describe a verification of the analytical performance of these assays and quantify their accuracy relative to established IFX and ADL TDM methods using pediatric specimens. Methods The reportable ranges of the Procise IFX (1.2 to 50.0 µg/mL) and ADL (1.0 to 50.0 µg/mL) assays were verified using calibration standards (N=6) prepared in pooled serum. Assay precision was determined through intra- and inter-day studies (N=20) with the Procise IFX and ADL quality control (QC) material (N=2). Patient results from the Procise IFX assay were correlated with an electrochemiluminesence immunoassay (ECLIA, reference laboratory A) and a liquid chromatography tandem mass spectrometry method (LC-MS/MS, reference laboratory B). ADL patient results from the Procise assay were correlated with an ECLIA (reference laboratory A) and an enzyme linked immunosorbent assay (ELISA, reference laboratory B). Reflexive IFX and ADL antidrug antibody testing may be performed when their drug concentrations are below 5.1 and 8.0 µg/mL, respectively. The performance of the Procise IFX and ADL assays near these thresholds were assessed through intra- and inter-day (N=20) precision studies with spiked pooled serum. Results The reportable ranges of the Procise IFX (slope=1.021, R^2 = 0.9988) and ADL (slope=0.998, R^2=0.9991) assays were verified. Intra-day precision of the QC for the Procise IFX (%CV=10.9% and 4.7%) and ADL (%CV=6.1% and 2.3%) assays were acceptable. The inter-day precision of Procise IFX and ADL QC did not respectively exceed 8.8% and 5.4%. Patient specimen correlation between the Procise and ECLIA IFX assays showed a consistent negative bias (Deming regression: y=0.773x+0.29, R=0.9688, bias=-3.3 µg/mL or -20.9%, N=30). An analogous correlation with the IFX LC-MS/MS assay demonstrated a higher level of concordance (Deming regression: y=0.902x+0.29, R=0.9894, bias=-1.1 µg/mL or -7.8%, N=20). A consistent positive bias was observed in the patient specimen correlation between the Procise and ECLIA ADL assays (Deming regression: y=1.175x+0.32, R=0.9347, bias=3.0 µg/mL or 19.6%, N=30), The results from the Procise and ELISA ADL correlation were largely concordant (Deming regression: y=1.173x-2.42, R=0.9436, bias=0.5 µg/mL or 3.0%, N=20). Serum pools spiked with 2.0 and 8.0 µg/mL of IFX had an average recovery of 95% and intra- and inter-day precisions below 5.7% and 7.6%, respectively. The achieved intra- and inter-day precision of serum pools spiked with 4.0 and 12.0 µg/mL of ADL did not respectively exceed 5.0% and 10.0% and had an average recovery of 108%. Conclusion The analytical performance of the Procise IFX and ADL serum assays was verified. Patient results exhibited minimal bias relative to established ECLIA, LC-MS/MS and ELISA-based assays. The FDA-clearance, significantly improved turnaround time, and accuracy of these tests make the ProciseDx system an attractive alternative platform for routine pediatric TDM of IFX and ADL.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

B-408 Evaluation of the infliximab and adalimumab therapeutic drug monitoring tests from ProciseDx in a pediatric setting — Science Skim