B-391 A Ready-to-Run Workflow for Quantitating 80 Drugs of Abuse in Whole Blood with the TSQ Certis Triple Quadrupole MS
Jingshu Guo, Courtney Patterson
Key points
From the paper's conclusion- This workflow presents an end-to-end solution for the quantitation of 80 commonly encountered drugs of abuse in whole blood using the TSQ Certis triple quadrupole mass spectrometer.
Abstract
Background The accurate and reliable quantitation of drugs of abuse in whole blood is critical for forensic toxicology and clinical research investigations. Analytical laboratories face ongoing challenges in meeting increasing demands for high-throughput, sensitive, and reproducible testing while maintaining compliance with regulatory standards. This workflow presents an end-to-end solution for the quantitation of 80 commonly encountered drugs of abuse in whole blood using the TSQ Certis triple quadrupole mass spectrometer. The workflow integrates efficient sample preparation, robust chromatographic separation, and optimized mass spectrometric detection to deliver exceptional sensitivity, selectivity, and quantitative accuracy. Methods A total of 80 target analytes were prepared into a mix to be spiked into negative human whole blood. Calibration standards were then prepared at 13 levels ranging from 0.05 to 500 ng/mL in whole blood to a volume of 100 µL. Samples were spiked with 15 µL of internal standard (ISTD) stock comprised of the labeled standards of each of the 80 drugs. A protein crash was performed with 25 µL of 1% Zinc Sulfate (ZnSO4) and 300 µL of acetonitrile. Samples then underwent INTip™ Filtration using Tip-on-Tip™ (ToT) technology from DPX Technologies. Samples were dried down and reconstituted with 20 µL of methanol (MeOH) + 0.1% formic acid + 2 mM ammonium formate and 80 µL of H2O + 0.1% formic acid + 2 mM ammonium formate. Data was acquired on the TSQ Certis mass spectrometer using SRM mode for quantitative and confirming transitions for each target compound and a quantitative transition for the internal standards. Q1 resolution was 0.7 FWHM and Q3 1.2 FWHM. The SRM list contained the retention times, precursor and product ions m/z, optimized RF lens voltages and collision energies, and retention times. Data was acquired and processed with Thermo Scientific™ TraceFinder™ software, version 5.2. Results This workflow helped achieve LOQs as low as 0.05 ng/mL with ULOLs up to 500 ng/mL. The LOQ and ULOL of each analyte is shown in Table 4. The TSQ Certis mass spectrometer uses the Thermo Scientific™ OptaMax™ Plus HESI source which allows for increased vaporizer temperatures, improving the relative peak areas and overall sensitivity for drugs of abuse. Utilizing a vaporizer temperature of 500°C helped achieve improved sensitivity. A robustness study was performed by injecting extracted whole blood spiked with drugs of abuse for over 450 injections. Peaks areas were monitored from injection to injection. Lorazepam peak areas over time were well within a +/-20% RSD. Conclusion This fast, quantitative TSQ Certis mass spectrometry method was used to detect and confirm 80 drugs of abuse and their corresponding internal standards, including positive and negative polarities, in whole blood in a 4.5-minute method.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- B-421 Validation of high-resolution mass spectrometry-based targeted drug screeningClinical Chemistry · 2026
- B-419 Rapid and Automated Magnetic Bead–Based Sample Preparation for Multi-Class Drugs of Abuse Analysis by LC–MS/MSClinical Chemistry · 2026
- B-403 Validation of a high-resolution mass spectrometry-based comprehensive drug testClinical Chemistry · 2026
- Analysis of eight OTC drug components in postmortem dried blood spot samples by liquid chromatography-tandem mass spectrometry.Legal medicine (Tokyo, Japan) · 2026
- Ambient ionization mass spectrometry for rapid screening of illegal adulteration in traditional Chinese medicines: a reviewAnalytical Methods · 2025
- Mass Spectrometry-Based Anti-Doping Analysis: A Critical Review of Emerging Analytical and Sample Pretreatment Strategies.Critical reviews in analytical chemistry · 2026