  • Magnetic bead–based extraction utilizing a weak cation exchange (WCX) sorbent offers a streamlined, 96-well plate-based alternative, providing rapid sample processing and producing cleaner extracts with improved signal-to-noise ratios.

Abstract

Background Metanephrine (MN) and normetanephrine (NM), O-methylated metabolites of epinephrine and norepinephrine, are markers utilized in the evaluation of suspected pheochromocytoma and paraganglioma. Accurate LC MS/MS quantitation requires effective sample cleanup to remove matrix interference. Our current clinical method utilizes cartridge-based solid-phase extraction (SPE); however, this technique, while analytically established, necessitates multiple conditioning, washing, and elution steps, increasing hands-on time and limiting batch scalability. Magnetic bead–based extraction utilizing a weak cation exchange (WCX) sorbent offers a streamlined, 96-well plate-based alternative, providing rapid sample processing and producing cleaner extracts with improved signal-to-noise ratios. These workflow efficiencies prompted an evaluation of WCX magnetic bead extraction as a potential replacement for traditional SPE. Methods Matched plasma samples (0.5 µmL), spiked with an internal standard, were extracted in duplicate using either the current clinical SPE method or the WCX magnetic bead protocol. The clinical SPE method utilized Oasis WCX SPE cartridges (30 mg, 1 mL; Waters) according to the manufacturer's protocol, which involved conditioning, loading, and elution steps. For the magnetic bead extraction, WCX magnetic beads (3P BioSolutions Inc.) were conditioned in a 96-well format, mixed with plasma, separated magnetically, washed with water and acetonitrile, and eluted with 2% formic acid in acetonitrile:water (95:5). Eluates from both methods were dried (TurboVap, 20 min) and reconstituted to 100 µL using 0.1% formic acid in 1mM ammonium formate. Chromatographic separation was performed on a PFP propyl analytical column (3 µm, 2.1 × 100 mm; Restek) with mobile phase A (1mM ammonium formate + 0.1% formic acid in water) and mobile phase B (1mM ammonium formate in methanol + 0.1% formic acid). LC–MS/MS analysis utilized positive electrospray ionization with selected reaction monitoring of MN (m/z 180.1 ->148.1), NM (m/z 166.1 ->134.1), metanephrine-IS (m/z 183.1 ->168.1), and normetanephrine-IS (m/z 169.1->137.1). Results Plasma samples (N=12) were analyzed using both methods, with concentrations ranging from 9.9 to 317 pg/mL for MN and 23.8 to 905 pg/mL for NM, covering the AMR. Analyses performed with the EP Evaluator (Data Innovations LLC) showed mean biases of 1.64 pg/mL (2.36%) and 16.94 pg/mL (11.98%) for MN and NM, respectively. Deming regression confirmed strong linear agreement between the methods with slopes of 1.115 for MN and 1.125 for NM. The mean QC bias relative to the production method was –0.5% for MN and –11.1% for NM. Both methods exhibited similar retention times and Gaussian peak shapes, with analyte signal approximately 1.3-fold higher in the magnetic bead-based extract compared with traditional SPE. Conclusion WCX magnetic bead extraction demonstrated analytical equivalence to the production SPE method for MN and a modest positive shift for NM, with excellent linear agreement between methods. Operationally, the magnetic bead workflow is substantially faster (∼15 min) than cartridge-based SPE (∼1.5 h) and reduces manual handling in a 96-well format, facilitating automation. These efficiencies are expected to reduce labor and per-batch operating costs compared with traditional SPE; further validation will be performed prior to replacing the current production SPE method.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers