B-362 Systematic optimization of an LC–MS/MS method to improve peak shape, calibration stability, and carryover in a multi-antibiotic assay for serum and CSF
Chao Sun, Zara Jalali, Yi Xiao, Edward Leung
Key points
From the paper's conclusion- We performed systematic optimization to reduce degradation, improve chromatographic performance, and ensure analytical stability over prolonged analytical runs.
Abstract
Background Ceftazidime and ceftriaxone demonstrated split peaks, calibration variability, analyte instability, and significant carryover in a multi-analyte LC–MS/MS assay. Split peaks compromise integration accuracy, and carryover may introduce positive bias at low concentrations. ß-lactam antibiotics are susceptible to degradation during extraction and autosampler storage. We performed systematic optimization to reduce degradation, improve chromatographic performance, and ensure analytical stability over prolonged analytical runs. Methods Experiments were conducted on Waters Xevo-G3 Q-TOF and TQ Absolute Triple Quadrupole mass spectrometers. To assess non-stabilized extracted samples, calibrators and QCs prepared without pH adjustment were injected at 0, 8, and 24 hours, and changes in peak area and peak morphology were evaluated. Multiple stabilization strategies were simultaneously implemented to reduce degradation. To reduce degradation, samples and stock solutions were adjusted to pH 5 using an acetic acid/acetate buffer system, as ß-lactams are most stable between pH 4.5 and 6.5. Samples were prepared on ice and maintained at approximately 4 °C prior to injection, and stock solutions were stored in amber tubes to minimize light exposure. To reduce split peaks, extracted samples were diluted to 90:10 H2O:MeOH to better match the strongly aqueous initial mobile phase and minimize solvent-induced peak distortion. In addition, stock solutions were remade by reducing the ceftazidime DMSO content from 100% to 2%, which further improved peak shape and reduced peak splitting. MS transitions for ceftazidime were compared to identify the most stable quantifier ion. Injection volumes (5 vs 10 µL) and gradient starting conditions (2%, 4%, 7%, 10% MeOH) were evaluated. Carryover mitigation strategies included extending autosampler pre- and post-wash times to 20 seconds and incorporating high-organic gradient washout segments. Calibration stability was evaluated over 8 and 24 hours using eight calibration levels in water, CSF, and serum. Linearity, slope variation, bias, and %CV were assessed. Results Reinjection of non-stabilized extracted samples demonstrated a 12–81% reduction in analyte peak areas at 24 hours and progressive peak distortion, confirming degradation during autosampler storage. After implementing pH adjustment to 5 with acetate buffer, analyte peak areas remained within ±5% over 24 hours and peak morphology remained stable. Matching the injection solvent to 90:10 H2O:MeOH reduced split peaks. The 547.032?166.95 transition for ceftazidime produced improved peak symmetry compared with the primary transition. Calibration curves remained linear at both 8 and 24 hours, with slope variation of =3.1%. QC repeatability demonstrated %CV =6.0% across matrices over 24 hours. Initial ceftriaxone carryover measured 24% in the first blank; incorporation of gradient washout reduced blank response to <2.5%, remaining <2.5% after multiple consecutive high-concentration injections. Conclusion Improved analytical performance was achieved by reducing DMSO to 2%, adjusting samples to pH 5 using acetic acid/acetate buffer, controlling temperature and light exposure, matching injection solvent to the initial gradient, optimizing MS transitions, and incorporating gradient washout steps, we significantly reduced degradation and carryover while maintaining chromatographic performance. The optimized method sustained calibration and QC stability for at least 24 hours and reduced carryover from 24% to 2.5%.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Analytical instability and aqueous degradation of carbapenem antibiotics: formation of β-lactam-retaining transformation products.Ecotoxicology and environmental safety · 2026
- B-418 Simultaneous LC-MS/MS quantification of Cefepime, Meropenem, Piperacillin and Tazobactam in pediatric serum: method validation for therapeutic drug monitoringClinical Chemistry · 2026
- LC-MS/MS method for simultaneous quantification of antibiotics in dialysis effluent and human serum for routine therapeutic drug monitoring.Scandinavian journal of clinical and laboratory investigation · 2026
- Integrated persulfate/ozonation process using Fe3O4/AC catalyst for antibiotic degradation: optimization and kinetic insightsScientific Reports · 2025
- Quantification of antimicrobials and surfactants in drain biofilms: rapid extraction and comprehensive LC-MS/MS analysis.Analytical methods : advancing methods and applications · 2026
- B-342 Long run LC–MS/MS robustness in human plasma: a 30,000-injection evaluation of quantitative stability, carryover, and uptime on a triple quadrupole platform for clinical researchClinical Chemistry · 2026