Clinical Chemistry

B-323 Optical Sensor for Plasmid DNA QC in Biofoundry Workflows

ChangHa Woo, Chanyong Park

Key points

From the paper's conclusion
  • This study develops a multi-channel UV absorbance sensing module compatible with 96-well measurements and evaluates its performance using standard materials.

Abstract

Background In Biofoundry workflows, rapid and high-throughput quality control of plasmid DNA is essential for automated library construction and process optimization. UV absorbance at 260 nm and 280 nm enables simultaneous quantification of nucleic acids and assessment of protein contamination via the A260/A280 ratio in a 96-well format. However, sensor options in the UV-C region are limited, and some high-sensitivity detector approaches impose constraints on multi-channel array implementation due to cost and operating requirements. This study develops a multi-channel UV absorbance sensing module compatible with 96-well measurements and evaluates its performance using standard materials. Methods A UV-C photodetector optimized for the 200–320 nm range was selected considering performance, size, and cost. UV-LEDs targeting 260 nm (DNA) and 280 nm (protein) were adopted (˜10 nm bandwidth; =5° collimation, bulb-type package). An 8-channel absorbance sensing module was implemented by fabricating boards populated with eight photodetectors and eight UV-LEDs, together with a main control board integrating an MCU, data acquisition/communication, and external power ports. Wavelength-specific LED on/off control and real-time monitoring of photodetector outputs were implemented, enabling raw signal readout at 260/280 nm and A260/A280 ratio calculation with =10 Hz acquisition and signal averaging. A 96-well microplate measurement setup was built using a custom XYZ translation stage integrated with the sensor module. Precision was assessed by 25 repeated measurements of DI water (blank), Lambda DNA (280 µg/mL), and BSA (10 mg/mL). Quantitative ranges were evaluated via serial dilutions of Lambda DNA (measured at 260 nm) and BSA (measured at 280 nm). Results Baseline stability for blanks showed low variability with CVs of 0.52% (260 nm) and 0.25% (280 nm). For Lambda DNA (280 µg/mL), repeatability was CV 4.7% at 260 nm and CV 1.33% at 280 nm, indicating stable performance even under relatively low transmitted intensity at 260 nm. For BSA (10 mg/mL), CVs were 1.17% (260 nm) and 1.01% (280 nm), demonstrating ∼1% repeatability at both wavelengths. Serial dilution experiments showed concentration-dependent transmittance changes, supporting a quantifiable range of ∼2.8–280 µg/mL for Lambda DNA and ∼1–10 mg/mL for BSA under the tested conditions Conclusion An 8-channel UV absorbance sensor module operating at 260 nm and 280 nm was developed and integrated with a 96-well compatible XYZ translation platform (Figure 1). The system demonstrated excellent repeatability (CV 0.25–0.52% for blanks and ∼1–4.7% for DNA/protein standards) and clear quantitative ranges for nucleic acid and protein standards. This platform enables high-throughput plasmid DNA quantification and A260/A280-based QC in a microplate format.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers