Clinical Chemistry

B-280 Diagnostic Performance of Two Fecal Calprotectin Assays in an All-Comer Population Undergoing Evaluation for IBD

Lezlie Kelzenberg, Ashli Rode, Claudia Zierold, Dat Vo

Key points

From the paper's conclusion
  • Nevertheless, with areas under the curve of ∼0.8, both assays leave room for improvement to better align with clinical diagnosis and potentially reduce unnecessary colonoscopies.

Abstract

Background Fecal calprotectin, derived from neutrophil proteins S100A8/A9, is a non-invasive marker of intestinal inflammation that correlates with disease activity. Inflammatory bowel disease (IBD) affects millions worldwide and presents with nonspecific symptoms overlapping with irritable bowel syndrome and other gastrointestinal disorders, complicating diagnosis. Colonoscopy with biopsy remains the gold standard but is invasive and burdensome. Calprotectin testing provides a useful tool to distinguish IBD from non-IBD, but its clinical use is limited by assay variability and the lack of standardized cut-offs. This study aimed to compare the diagnostic performance and agreement of two fecal calprotectin assays in patients evaluated for IBD. Methods All-comer patients presenting with signs and symptoms suggestive of IBD and scheduled for colonoscopic evaluation for were enrolled. IBD diagnosis was confirmed by endoscopic and histologic findings. The cohort included 210 patients (median age 50, 63% female), of whom14% were diagnosed with IBD). Fecal samples were collected and processed using kit-specific extraction devices, then tested with both the LIAISON® Calprotectin assay and the Bühlmann fCal® Turbo assay. The primary endpoint was concordance between assays and their ability to distinguish IBD from non-IBD. Results Results were classified as normal, elevated, or borderline (gray zone) for each assay and compared. Inter-rater agreement yielded a kappa of 0.72 (95% CI, 0.63–0.80), indicating good concordance. Among 32 discordant samples, 2 were from IBD patients correctly classified by the LIAISON® assay but not by the Bühlmann fCal® Turbo assay. Of the remaining 30 non-IBD samples, the LIAISON assay classified 8 as normal, 21 as borderline, and 1 as elevated, while the Bühlmann assay classified 12 as normal, 5 as borderline, and 13 as elevated. Positive percent agreement between the two assays, considering borderline results as positive, was 82.9% (95% CI, 73.0 to 90.3%), and negative percent agreement was 93.8% (95% CI, 88.1% to 97.3%). Receiver operating characteristic analysis for IBD versus non-IBD diagnosis showed no significant difference between the two assays, with areas under the curve of 0.819 (95% CI, 0.717–0.922) for the LIAISON assay and 0.798 (95% CI, 0.698–0.898) for the Bühlmann assay (p = 0.25). Conclusion The LIAISON® Calprotectin and Bühlmann fCal® Turbo assays showed good agreement and comparable accuracy for distinguishing IBD from non-IBD. The LIAISON assay correctly classified most discordant IBD (elevated) and non-IBD (normal) cases, while borderline results appropriately fall within a gray zone requiring follow-up for accurate diagnosis. Nevertheless, with areas under the curve of ∼0.8, both assays leave room for improvement to better align with clinical diagnosis and potentially reduce unnecessary colonoscopies.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

B-280 Diagnostic Performance of Two Fecal Calprotectin Assays in an All-Comer Population Undergoing Evaluation for IBD — Science Skim