B-244 The Effects of Technology Integration for Communication with Confirmatory ANCA Testing
Ashley Denome, Nou Her, Melissa Snyder
Key points
From the paper's conclusion- Data was collected retrospectively on 418 discrepant ANCA results, documenting the time from medical director request to result reported, estimated time spent on communication, and the number of confirmatory tests per patient, for the 10 months preceding the database inauguration and for the 10 months after.
Abstract
Background Anti-neutrophil cytoplasmic antibodies (ANCA)-associated vasculitis is characterized by proteinase 3 (PR3) and myeloperoxidase (MPO) antibodies. PR3-ANCA and MPO-ANCA result in cytoplasmic and perinuclear staining, respectively, on ethanol-fixed neutrophils. However, discrepancies between solid-phase and immunofluorescence testing for ANCAs do occur; in these cases, review by laboratory directors is required, sometimes resulting in requests for repeat or confirmatory testing. Consequences of inadequate communication leads to overdue test results and possibly test cancellation due to exceeded specimen stability. The purpose of this project was to improve communication in the ANCA review process, with the goal of decreasing personnel communication time and improving turn-around time for results. Methods The current process for management of ANCA test review involved an E-mail notification to laboratory directors that pending result required review; after assessing the results, lab directors would E-mail management team, who would communicate with laboratory staff that additional testing was needed. Results from additional testing was summarized in a spreadsheet that could be reviewed by lab directors. In the new process, laboratory directors are notified by E-mail that a pending ANCA test requires review; if additional testing is needed, a web-based form is completed by laboratory directors. These requests are cataloged in an on-line database, which triggers logic to automatically notify laboratory testing personnel (created in Microsoft Power Automate). After testing is completed, a second on-line form is submitted by testing personnel to catalog results. When all required testing is complete, an automatic E-mail notifies laboratory directors. Data was collected retrospectively on 418 discrepant ANCA results, documenting the time from medical director request to result reported, estimated time spent on communication, and the number of confirmatory tests per patient, for the 10 months preceding the database inauguration and for the 10 months after. Results A total of 171 requests for additional ANCA testing were requested by laboratory directors from 1/25/2024 through 12/2/2024 utilizing the manual E-mail process; a total of 247 similar requests were managed through the online database process from 12/4/2024 through 10/8/2025. The average time from request to reported result decreased from 3 hours 17 minutes on the E-mail method to 3 hours 1 minute on the database method, corresponding to an 18% reduction. The maximum time from request to reported result decreased by 48% (20 hours 22 minutes to 10 hours 22 minutes for the E-mail and database methods, respectively). The amount of communication time also decreased by 45% for laboratory directors (1074 to 303 minutes) and by 99% for laboratory management staff (339 to 3 minutes). The number of process deviations, such as cancellations due to stability and samples requiring additional manual communication, reduced by 45% (11 for E-mail method and 6 for database method). Conclusion Utilization of the new database had substantial improvements within the testing process, resulting in reduced communication time between laboratory personnel, decreased time from request to result report, and fewer deviations. By utilizing technology to execute routine tasks, the laboratory has improved its quality metrics while maintaining high level of care with improved employee satisfaction.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Real-World Concordance of Indirect Immunofluorescence and Antigen-Specific Assays in Antineutrophil Cytoplasmic Antibody Testing: A Retrospective High-Volume Laboratory Study.The Eurasian journal of medicine · 2026
- ANCA practice in diagnostic pathology: state of play and unresolved challenges.Rheumatology (Oxford, England) · 2026
- Antineutrophil Cytoplasmic Antibodies: Integrating History, Pathogenesis, and Modern Diagnostics.International journal of rheumatic diseases · 2026
- ANCA testing in real-world clinical practice: diagnostic performance and predictive value in a Spanish cohortLara D. Veeken · 2026
- B-178 Comparative Performance of ANCA Indirect Immunofluorescence Assays and Concordance of Manual Versus Automated Interpretation in 583 SeraClinical Chemistry · 2026
- 182 Leveraging an Automated Delta-Check Rule to Flag Critical Preanalytical Errors in Coagulation Testing: A 14-Month Lab Practice InterventionAmerican Journal of Clinical Pathology · 2026