Clinical Chemistry

B-213 Clinical Performance of a Novel 4th-Generation HIV Ag/Ab Initial Screening Assay: High Sensitivity, Specificity and Broad Subtype Coverage

Junxi Tian, Zixi Liu, Enxue He, Chengyi Huang, Changgeng Chen, Renlin Li

Key points

From the paper's conclusion
  • The excellent sensitivity for early infection markers and broad genotype inclusivity, combined with outstanding specificity, makes this assay a highly reliable and robust tool for first-line HIV screening.

Abstract

Background Since its discovery, the Human Immunodeficiency Virus (HIV) has become a global pandemic and remains a significant public health challenge. Accurate and timely diagnosis is fundamental to ending the epidemic, as it links individuals to essential treatment and prevention services. Fourth-generation immunoassays, which simultaneously detect HIV-1/2 antibodies and p24 antigen (HIV Ag/Ab assays), are the current standard for first-line screening. By detecting the p24 antigen, these assays significantly shorten the diagnostic window period, enabling earlier detection of acute infections. Given the high genetic variability of HIV, screening assays must demonstrate both high sensitivity and broad viral subtype inclusivity to support effective public health management. This study evaluates the diagnostic performance of a novel HIV Ag/Ab Assays manufactured by Maccura Biotechnology Co., Ltd. (Chengdu, China). Methods The performance of the HIV Ag/Ab assays was evaluated against an established comparator, the Architect HIV Ag/Ab Combo Reagent Kit. First, the antigen sensitivity was assessed using a panel of 50 confirmed HIV Ag-positive clinical samples, 50 HIV-1 virus isolates (cell culture supernatants from diverse subtypes), and 42 commercial seroconversion panels sourced from SeraCare Life Sciences, ZeptoMetrix, and Biomex GmbH. Then, the antibody sensitivity was evaluated using 540 disease-stage-characterized samples, which included 356 samples covering HIV-1 group M subtypes, circulating recombinant forms (CRFs), unique recombinant forms (URFs), HIV-1 group O, and HIV-2. Finally, the specificity was determined by testing a cohort of 5094 healthy blood donors and 210 hospitalized patients. Results In terms of the antigen sensitivity, the assay correctly identified all 50 HIV Ag-positive samples and all 50 HIV-1 virus isolates as positive, yielding an overall antigen sensitivity of 100% (100/100; 95% CI: 96.3%-100%). The assay demonstrated reactivity against a broad range of HIV-1 subtypes, including A, B, C, D, F, G, O, and various CRFs. Across all 42 seroconversion panels tested, the assay demonstrated concordant results with the Architect comparator assay. In the case of antibody sensitivity, the assay detected all 540 antibody-positive samples demonstrating 100% sensitivity (540/540; 95% CI: 99.3%-100%). It successfully identified all tested subtypes from HIV-1 Groups M and O, as well as HIV-2, as shown in Table 1. For specificity, no false-positive results were observed among the 5094 blood donor samples and 210 hospitalized patient samples. The resulting diagnostic specificity was 100% (5304/5304; 95% CI: 99.93%-100%). Conclusion This systematic evaluation demonstrates that the novel HIV Ag/Ab Chemiluminescent Immunoassay Kit exhibits exceptional analysis and screening performance. The excellent sensitivity for early infection markers and broad genotype inclusivity, combined with outstanding specificity, makes this assay a highly reliable and robust tool for first-line HIV screening.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

B-213 Clinical Performance of a Novel 4th-Generation HIV Ag/Ab Initial Screening Assay: High Sensitivity, Specificity and Broad Subtype Coverage — Science Skim