Clinical Chemistry

B-154 Pandemic-associated surge and post-pandemic persistence of false-reactive fourth-generation HIV Ag/Ab screening results: A six-year single-center analysis

Sheng Feng, Mengjie Li, Hui Chen, Kristie Johnson, Robert Christenson

Observational

Key points

From the paper's conclusion
  • This study aims to investigate the frequency of false-reactive HIV-1/2 Ag/Ab screening results before, during, and after the COVID-19 pandemic and the associate patient factors at a large academic medical center.

Abstract

Background Fourth-generation HIV-1/2 antigen/antibody (Ag/Ab) combination assays enable earlier detection of acute infection. However, false-reactive screening results trigger additional testing and patient anxiety. Large-scale analyses of false-reactive spanning the COVID-19 pandemic in high-prevalence communities are lacking. This study aims to investigate the frequency of false-reactive HIV-1/2 Ag/Ab screening results before, during, and after the COVID-19 pandemic and the associate patient factors at a large academic medical center. Methods We conducted a retrospective study of all fourth-generation HIV-1/2 Ag/Ab combo assay performed from 2019 through 2024 in a tertiary care medical center in Baltimore, MD. Screening was performed using a chemiluminescent immunoassay platform with reflex testing per CDC-recommended algorithm, including HIV-1/2 antibody differentiation immunoassay and nucleic acid testing when indicated. A false-reactive result was defined as a reactive screening result with negative supplemental antibody differentiation and negative nucleic acid testing. False-reactive rates of HIV Ag/Ab combo assay were compared across pre-pandemic, pandemic, and post-pandemic periods. The association of false-reactive and patient factors, including age, race, gender, cancer status, and co-infections were assessed. Results Among 58,178 screens, 1,236 (2.1%) were reactive; 1,051 were true reactive and 185 were false-reactive (overall false-reactive rate 15.0% among reactive results). The false-reactive rate increased from 3.6-5.2% pre-pandemic to 17.9% at the onset of the COVID-19 pandemic and remained near 20% during the pandemic, declining to approximately 14% by 2024. In multivariable analysis, higher odds of false-reactive were observed for age >65, White race, and American Indian–Eskimo race. Coinfection of syphilis was associated with lower odds of false-reactive. Conclusion False-reactive HIV Ag/Ab screening results increased during the pandemic and remained elevated post-pandemic. Recognizing this temporal pattern and demographic associations can improve interpretation of reactive screens and reinforce confirmatory testing. Instrument signal-to-cutoff ratio (S/CO) distributions suggest post-pandemic re-evaluation of decision thresholds for the HIV Ag/Ab combo assay may be warranted.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers