Clinical Chemistry

B-209 Development and performance of an iTACT® dengue virus NS1 antigen detection reagent based on a chemiluminescent enzyme immunoassay

Chihiro Tanaka, Natsuko Kuroda, Tsuyoshi Ando, Kazuya Takahashi, Daisuke Nambara, Satoshi Kojima, Katsumi Aoyagi

Key points

From the paper's conclusion
  • Conclusion The iTACT detection reagent for DENV NS1 antigen, developed as a fully automated immunoassay system, exhibited satisfactory performance.

Abstract

Background Dengue fever is an acute febrile infection caused by the mosquito-borne dengue virus (DENV) and is highly prevalent in tropical regions. Four DENV serotypes exist, and secondary infection with a heterologous serotype increases the risk of developing severe disease. Nonstructural protein 1 (NS1) of DENV is used as a diagnostic marker for dengue fever. As NS1 is produced in infected cells and secreted into the extracellular space, its detection is useful in the diagnosis of acute dengue infection. However, in secondary infections, the immune complexes formed between the NS1 antigen and anti-NS1 antibodies may reduce the detection sensitivity. To enable reliable detection of the NS1 antigen in the presence of antibodies, we developed a DENV NS1 antigen detection reagent based on a chemiluminescent enzyme immunoassay (CLEIA) using our proprietary iTACT (immunoassay for Total Antigen including Complex via preTreatment) technology and reported its basic analytical performance. Methods Reagent: This reagent detects DENV NS1 in serum or plasma using a two-step sandwich method based on CLEIA. Samples (30 µL) were manually pretreated with 60 µL of pretreatment solution to inactivate endogenous antibodies, followed by the addition of 30 µL of the other pretreatment solution. Pretreated samples were analyzed using the fully automated LUMIPULSE® G1200 immunoassay system (Fujirebio Inc.). Results were reported as a cutoff index (C.O.I.), calculated as the ratio to the cutoff value from the positive control; C.O.I. values below 1.0 were interpreted as negative and values of 1.0 or higher were interpreted as positive. Correlation Study: A total of 48 DENV-positive and 50 DENV-negative specimens were tested to evaluate the concordance between iTACT and RT-PCR results. In addition, a DENV antibody-positive panel (SeraCare) was used to verify the assay interpretation. Specificity Study: Specificity was evaluated using 1,654 samples from healthy controls. Repeatability: The 1:1000 diluted positive samples of each DENV serotype were measured in six replicates to evaluate serotype-specific reactivity and repeatability. All samples used in this study were obtained in full compliance with the ethical and regulatory criteria. Results Correlation Study: Qualitative agreement with RT-PCR was 100%. Among the DENV antibody-positive panels, only one sample was reported to be NS1-positive using other methods; however, four samples were determined to be positive using this assay. Specificity Study: All healthy control samples were determined to be negative with C.O.I. values of 0.3 or lower. Repeatability: The assay demonstrated highly sensitive detection of the NS1 antigen for all four DENV serotypes. The coefficient of variation of the samples ranged from 3.0 to 3.8%. Conclusion The iTACT detection reagent for DENV NS1 antigen, developed as a fully automated immunoassay system, exhibited satisfactory performance. This assay enabled a high-sensitivity detection of all four DENV serotypes. The NS1 antigen was detected even in samples containing anti-DENV NS1 antibodies that were reported to be NS1-negative by other methods. Because the assay is less susceptible to interference from NS1 antigen–antibody immune complexes, it may be useful in both acute and secondary dengue infections.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers