B-160 Streamlining Syphilis Serology Through an Automated Multiplex Syphilis Total and RPR Panel
Xu Han, Weiming Zheng, Shuxia Zhou, Mariana Portella, Jeanine Schibler, Catalina Esteban-Christen, Scott Hauenstein, Russell Neuner
Key points
From the paper's conclusion- Conclusion The automated BioPlex Syphilis Total & RPR panel offers a high throughput, fully integrated solution that improves accuracy, reduces manual labor, and accelerates clinical decision making.
Abstract
Background Increasing global syphilis incidence has placed unprecedented demand on diagnostic laboratories, where conventional testing algorithms rely on separate treponemal and manual non-treponemal Rapid Plasma Reagin (RPR) steps. These fragmented algorithms create significant operational bottlenecks, increase hands-on time, and delay the delivery of test results. To address these challenges, a redeveloped, fully automated RPR assay was integrated with a treponemal Syphilis Total assay into a single multiplex panel on the BioPlex 2200 System. Methods The performance of the automated BioPlex Syphilis Total & RPR panel was evaluated in a combined cohort of 2,385 specimens. This included 842 healthy donors, 946 prospective clinical samples (including HIV positive and pregnant individuals and undergoing syphilis testing), and 597 retrospective samples with known infection or co-infection status. Assay accuracy and concordance were assessed by comparison with the BD Macro-Vue RPR card test and the DiaSorin LIAISON Treponema assay. Positive and negative agreement values were calculated for both prospective and retrospective groups. Prevalence estimates in healthy donors were also determined. Workflow efficiency and consolidation benefits were qualitatively assessed by comparing manual and automated processes. Results The automated BioPlex RPR assay demonstrated strong clinical agreement with the BD Macro-Vue RPR card test. In prospective samples, the automated RPR assay achieved 95.1% positive agreement (78/82) and 96.6% negative agreement (835/864). In retrospective samples, positive agreement was 97.4% (456/468) and negative agreement was 95.3% (123/129). The BioPlex Syphilis Total assay also demonstrated excellent agreement with predicate results, showing 96.8% positive agreement (175/181) and 98.0% negative agreement (750/765) in prospective samples, and 99.1% positive agreement (532/537) and 100% negative agreement (60/60) in retrospective samples. In healthy donors, the automated Syphilis Total and RPR assays reported prevalences of 1.0% (8/842) and 3.0% (25/842), respectively, compared with 3.7% (31/842) for the BD Macro-Vue RPR card test. Operationally, the multiplex panel with onboard titers consolidated two separate testing steps into one automated workflow, reducing manual intervention and minimizing error risk. Conclusion The automated BioPlex Syphilis Total & RPR panel offers a high throughput, fully integrated solution that improves accuracy, reduces manual labor, and accelerates clinical decision making. By simultaneously delivering treponemal and non-treponemal results, the assay eliminates the lag time of traditional reflex testing. This gain in laboratory efficiency supports faster clinical intervention, reduces patient loss-to-follow-up, and provides a scalable model for laboratories managing rising syphilis volumes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Stage-Specific Associations of Automated RPR With Treponema pallidum qPCR Positivity and Cycle Threshold in Early Symptomatic Syphilis: A Multicenter Study Using Specimens Collected During Routine CaremedRxiv · 2026
- B-034 An end to subjective RPR reading? Development of a novel nontreponemal immunoassay for syphilisClinical Chemistry · 2026
- B-190 Increasing Syphilis Positivity and the Importance of Validated Rapid Testing for Early Diagnosis and Disease Control StrategiesClinical Chemistry · 2026
- Rabbit intradermal inoculations as an efficient method to quantitate Treponema pallidum.Journal of medical microbiology · 2026
- Evaluation of Dual Path Platform optical density in relation to RPR titers and serological response in syphilis: a cross-sectional and longitudinal study.International journal of infectious diseases : IJID : official publication of the International Society for Infectious Diseases · 2026
- Analysis of influencing factors for syphilis serofast and development and evaluation of a predictive model.Frontiers in immunology · 2026