B-053 Development of a Chemiluminescent Enzyme Immunoassay (CLEIA) for the Measurement of NT-proBNP
Nanami Tadokoro, Eri Inagaki, Yuichiro Miyazawa, Yoshiharu Makiguchi, Aya Oshimo, Miki Tanaka, Yuichi Ishii, Yoshiyuki Kitamura,
Key points
From the paper's conclusion- These results indicate that the assay provides reliable NT-proBNP measurement with good comparability to an established commercial assay, supporting its suitability for clinical use.
Abstract
Background Heart failure is a major cardiovascular disease with high prevalence and mortality, and N-terminal pro-B-type natriuretic peptide (NT-proBNP) is a well-established biomarker for its diagnosis and management. With changes in patient demographics and therapeutic strategies, accurate measurement of NT-proBNP has become increasingly important. Compatibility of NT-proBNP immunoassays across analytical platforms remains an important practical consideration for clinical laboratories. In February 2026, a newly developed NT-proBNP assay based on a chemiluminescent enzyme immunoassay (CLEIA) principle was introduced in Japan for use on the LUMIPULSE® L2400 system. Methods The analytical performance of the NT-proBNP assay using in-house-generated monoclonal antibodies was evaluated on the LUMIPULSE L2400 system in accordance with CLSI guidelines. The system provides two measurement modes: a normal turnaround time mode (NT mode) and a short turnaround time mode (ST mode). The reaction times were approximately 20 minutes for NT mode and 14 minutes for ST mode, resulting in total analytical turnaround times of approximately 32 minutes and 26 minutes, respectively. The limit of quantitation (LoQ) was determined in both NT and ST modes, and the reported LoQ was defined as the higher (worse) value observed between the two modes. Precision, linearity, and method comparison were assessed in both NT and ST modes using clinical samples covering clinically relevant concentration ranges. Interference and reference interval determination were performed in NT mode only. Method comparison was conducted using patient samples in comparison with an established commercial NT-proBNP immunoassay. Results The limit of quantitation (LoQ) of the NT-proBNP assay was 5.5 pg/mL (NT mode: 5.0 pg/mL; ST mode: 5.5 pg/mL). Within-laboratory precision showed coefficients of variation (CVs) of = 1.7-2.4 % in NT mode and = 1.8-3.0 % in ST mode across evaluated concentration levels. Linearity was demonstrated over a wide concentration range of 3.7-60795.4 pg/mL in NT mode and 3.0-55543.5 pg/mL in ST mode. No significant interference in NT mode was observed from unconjugated (=20.0 mg/dL) or conjugated bilirubin (=19.7 mg/dL), chyle (=1420 FTU), hemoglobin (=520 mg/dL), triglycerides (=2000 mg/dL), HAMA (=1237 ng/mL) or rheumatoid factor (=1149 IU/mL) at clinically relevant concentrations. Using samples from apparently healthy individuals (NT mode), the reference interval for serum NT-proBNP was determined to be 8.3-180.5 pg/mL, with a median value of 31.0 pg/mL in NT mode. Method comparison using patient samples demonstrated good agreement with an established commercial NT-proBNP immunoassay. The correlation coefficient (r) and regression slope were 1.0 and 1.09 in NT mode, and 1.0 and 1.12 in ST mode. (n = 161) Conclusion The NT-proBNP assay demonstrated a low limit of quantitation, a wide analytical measuring range, good linearity, and good correlation with an established commercial NT-proBNP immunoassay. The availability of ST mode with analytical performance comparable to that of the NT mode may support NT-proBNP testing in time-sensitive clinical settings. These results indicate that the assay provides reliable NT-proBNP measurement with good comparability to an established commercial assay, supporting its suitability for clinical use.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- 5 Evaluating the Clinical Performance of FDA-Approved Alere NT-proBNPAmerican Journal of Clinical Pathology · 2026
- Individualized reference values for NT-proBNP in chronic heart failure: a Bayesian method to enhance biomarker-based patient monitoringEuropean Heart Journal · 2026
- A-016 Changes of NT-proBNP during hospitalization predict 12-month outcomes in heart failureClinical Chemistry · 2026
- B-214 Analytical Performance Evaluation of the ST2 Assay on the Maccura Immunoassay Platform in Dual-ModeClinical Chemistry · 2026
- Pre-randomization NT-proBNP trajectory and outcomes in the VICTOR trialEuropean Heart Journal · 2026
- Natriuretic Peptides for Predicting Treatment Response in Heart Failure: Insights From Recent Randomized Controlled Trials.International journal of heart failure · 2026