B-032 On-board Stability and Multi-Manufacturer Comparison of Maccura Enhanced Alkaline Phosphatase Assay

Lijuan Shi, Changying Wu, Yuchuan Liu, Yue Wang, Jue Wang, Renlin Li

Key points

From the paper's conclusion
  • Conclusion Based on the innovative assay formulation design, the on-board stability of the Maccura ALP assay is significantly superior to that of five commercially available similar products, which ensures the reliability of test results and effectively extends the calibration cycle.

Abstract

Background Alkaline phosphatase (ALP) is a hydrolase enzyme responsible for dephosphorylation of various molecules, including proteins, nucleotides, and alkaloids. It is widely distributed in human tissues, with the highest concentrations found in liver, bone, intestine, kidney, and placenta. In human serum, ALP primarily originates from liver and bone. Elevated serum ALP level holds significant reference value for the screening of hepatobiliary diseases and bone disorders associated with increased osteoblastic activity. However, a critical factor compromising the analytical accuracy of ALP assays is the on-board stability of reagents. Once opened, reagents are exposed to atmospheric carbon dioxide, which dissolves in the alkaline buffer to form carbonic acid, progressively lowering pH. This pH drift causes spurious decreases in apparent ALP activity, potentially leading to falsely low patient results and diagnostic errors. To mitigate this limitation, we designed and optimized the assay formulation with enhanced resistance to atmospheric carbon dioxide, which improves its on-board stability. A comparative evaluation of the on-board stability for reagents was conducted between our optimized assay and five commercially available ALP assays, aiming to provide a reliable performance reference for clinical laboratory testing. Methods The comparative evaluation of reagents’ on-board stability was conducted on HITACHI 7180 analyzers using Randox quality control (QC) materials, following calibration of the ALP assays from Maccura and five other manufacturers (designated as A, B, C, D, and E). In terms of the concrete details, two levels of quality control materials were tested twice daily for a 30-day period. The first run was performed at the start of each day, and the second run was conducted 5 to 10 hours later. Relative deviation (RD) and coefficient of variation (CV) were calculated for both evaluations. Results In this study, the CV values of the ALP assay on HITACHI 7180 analyzers for Assays A, E and Maccura were 14.85%–15.95%, 10.92%–11.55%, 4.36%–6.87%, 8.42%–9.29%, 15.89%–16.32% and 2.06%–3.03%, respectively. Notably, the Maccura ALP assay exhibited the lowest CV values across both QC levels, indicating superior analytical precision. For QC Level 1, the maximum relative deviation (RD) of the measured ALP activities for the Maccura assay was -9.38%, whereas the maximum RD values for the other commercial assays ranged from -20.51% to -43.40%. For QC Level 2, the maximum RD for the Maccura ALP assay was -5.30%, and those of other manufacturers ranged from -12.02% to -41.95%. Notably, only the RD of Maccura ALP remained within the control limits ( ± 10%) after 30 days of analysis following reagent opening and on-board incubation on the analyzer. Conclusion Based on the innovative assay formulation design, the on-board stability of the Maccura ALP assay is significantly superior to that of five commercially available similar products, which ensures the reliability of test results and effectively extends the calibration cycle.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers