B-019 Operational and Economic Impact of Turnaround Time Target Exceedance in a High-Volume Automated Clinical Laboratory
KyungYi Kim, Sunwoo Kim, Sang Gyu Lee
Key points
From the paper's conclusion- These findings support incorporating exceedance-based metrics into laboratory performance evaluation frameworks.
Abstract
Background Turnaround time (TAT) is a core performance metric in automated clinical laboratories. Although mean TAT is commonly reported, operational strain is largely driven by the proportion of tests exceeding predefined clinical targets. We evaluated the economic implications of TAT exceedance using a hospital-wide dataset comprising 1,182,419 tests per month in a tertiary care center. Emergency tests were assessed against a 60-minute target and routine tests against a 120-minute target. Methods Laboratory performance was modeled using an operations management framework based on Little’s Law, treating patients as inventory and TAT as flow time. Kernel density estimation of post-automation TAT distributions demonstrated that 42.1% of emergency tests exceeded the 60-minute target, with a mean excess delay of 8.4 minutes per emergency test. Routine tests showed a 35.6% exceedance rate beyond 120 minutes. Clinical pathways were stratified as follows. Emergency department (ED) testing was assumed to consist entirely of emergency orders, where TAT excess was translated into increased ED length of stay (LOS) and reduced throughput capacity. For inpatients, emergency TAT excess was conservatively allocated 50% to waiting-time burden and 50% to LOS extension, assuming a 0.5-day LOS increase in 30% of affected cases. Outpatient emergency excess was modeled as waiting-time burden. Routine test exceedance was conservatively down-weighted to reflect lower immediate operational impact. Economic impact was estimated from the hospital perspective using contribution margin per ED visit and per inpatient bed-day. Results Emergency TAT exceedance generated approximately 255,500 cumulative delay hours annually, equivalent to 10,646 patient-days or nearly 29 patient-years of lost flow time. When translated into workforce equivalents, this corresponds to approximately 128 full-time staff-years of operational delay. Under an assumed ED LOS of 4 hours, cumulative excess delay was associated with substantial ED throughput displacement. Combined ED capacity loss and inpatient LOS extension were associated with an estimated annual opportunity cost exceeding USD 20 million per tertiary hospital under base-case assumptions. Conclusion TAT exceedance represents a measurable operational and financial burden beyond traditional quality metrics. Even modest per-test delays accumulate into significant system-level capacity loss in high-volume laboratory settings. Distribution-aware performance monitoring and real-time workflow optimization may enable laboratories to reclaim latent capacity without structural expansion. These findings support incorporating exceedance-based metrics into laboratory performance evaluation frameworks.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- B-020 Efficiency Analysis of Automated Clinical Laboratories Based on Specimen Transport Logics and Track Layouts Using a Digital TwinClinical Chemistry · 2026
- Where is the delay? A phase-wise analysis of turnaround time in a veterinary biochemistry laboratory.Frontiers in veterinary science · 2026
- Improving Diagnostic Turnaround Time and Analytical Reliability in Clinical Biochemistry Laboratories: A Quality Management FrameworkInternational Journal of Latest Technology in Engineering Management & Applied Science · 2026
- Histopathology turnaround time analysis: identifying bottlenecks and implementing mitigation strategies in a multi-site laboratory.Journal of histotechnology · 2026
- A-269 Project Management Applied to Large-Scale Laboratory Technology Modernization in an Integrated diagnostics network: Operational Gains and Significant TAT ReductionClinical Chemistry · 2026
- A-013 Turnaround Time Performance for Troponin I in a Core LaboratoryClinical Chemistry · 2026