B-014 Clinical Validation of the IntelliSep® Host-Response Sepsis Test in the Absence of a Reference Standard
Alyssa Hutto, Kimberly Labrado, Karla Guier
Key points
From the paper's conclusion- Conclusion We successfully validated the accuracy of the IntelliSep® sepsis diagnostic test without access to a gold standard reference.
Abstract
Background Evaluating diagnostic test performance typically relies on comparison to a reference standard with minimal error (i.e. a “gold standard”). However, when new tests emerge for diseases without a historically reliable indicator, laboratories must develop alternative methods to validate diagnostic performance. Accuracy can be particularly challenging to assess without a reference standard. Sepsis is a complex syndrome that currently has no gold standard diagnostic test. Recently, we validated IntelliSep®, an FDA-cleared test to aid in the early detection of sepsis with organ dysfunction manifesting within 3 days of testing. IntelliSep® assesses cellular host response to generate an IntelliSep® Index (ISI) that falls within three discrete interpretation bands which indicate a low (Band1) to high (Band 3) probability of sepsis with organ dysfunction manifesting within three days. Method The IntelliSep® test is performed on 100 µL of K2EDTA anticoagulated whole blood. Remnant CBC samples from patients meeting selection criteria were used for testing. Patients were selected based on clinical characteristics and treatment consistent with a low or high likelihood of sepsis. Patients with a low likelihood of sepsis had a CBC order and were pending discharge. Patients with high likelihood of sepsis had 2+ Systemic Inflammatory Response Syndrome (SIRS) criteria of which one was an elevated temperature or abnormal WBC, orders for blood cultures and antimicrobials, and were pending admission. The criteria were selected to increase the likelihood of results in interpretation Bands 1 and 3. IntelliSep® results not consistent with the low or high likelihood inclusion criteria (e.g. a low likelihood candidate resulting in a Band 3) were labeled as discordant. Following testing, all discordant results and 6 concordant results were submitted for physician case review. Physicians assigned “sepsis” or “not sepsis” labels following a structured adjudication scheme modeled on the validation study described in the IFU. Final accuracy validation was assessed by comparison of the percentage of septic patients in Band 1 and 3 to the IFU. Results A total of 44 patients were evaluated with IntelliSep® results distributed as follows: 28 Band 1 (low likelihood of sepsis), 6 Band 2 (moderate likelihood of sepsis), and 10 Band 3 (high likelihood of sepsis). No low likelihood patients produced a Band 3 result, while 9 high likelihood patients produced a Band 1 result. After physician adjudication, only one discordant result was labeled septic, while two patients with a high likelihood of sepsis were adjudicated as not septic. Ultimately, the percentage of septic patients was observed to be 3.6% in Band 1 and 80% in Band 3, consistent with the diagnostic accuracy reported in the IntelliSep® IFU. Conclusion We successfully validated the accuracy of the IntelliSep® sepsis diagnostic test without access to a gold standard reference. Key aspects of the study design were clinical selection criteria designed to enrich the sample population with results needed for comparison to the IFU as well as close modelling of result evaluation to the validation study cited in the product
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Ruling In and Ruling Out Sepsis Using Likelihood Ratios of a Host Response Assay.Diagnostics (Basel, Switzerland) · 2026
- Validation of SeptiCyte RAPID to Discriminate Sepsis From Noninfectious Systemic Inflammation in Critically Ill Children.Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies · 2026
- Sequential Application of Time-Stratified Demographic, Vital, Clinical-Laboratory, and Microbiology Variables for Accurate and Rapid Identification of Sepsis.Diseases (Basel, Switzerland) · 2026
- Diagnostic accuracy of SeptiCyte® RAPID to discriminate sepsis from non-infectious critical illness in patients meeting sepsis criteria according to sepsis-3 definition at ICU admissionEuropean Journal of Clinical Microbiology & Infectious Diseases · 2026
- A-297 Impact of the Implementation of a Host-Response Sepsis Test on Blood Culture Utilization and Contamination RatesClinical Chemistry · 2026
- B-250 Impact of the Implementation of a Host-Response Sepsis Test on Sepsis Alerts and Laboratory Sepsis Resource use in the Emergency DepartmentClinical Chemistry · 2026