Clinical Chemistry

A-297 Impact of the Implementation of a Host-Response Sepsis Test on Blood Culture Utilization and Contamination Rates

Alyssa Hutto, Karla Guier

Observational

Key points

From the paper's conclusion
  • These findings suggest that using HRST can streamline sepsis evaluations, lessen laboratory workload, and potentially reduce the downstream clinical costs associated with false-positive blood cultures.

Abstract

Sepsis remains a primary driver of hospital morbidity and mortality, necessitating rapid and accurate diagnostic pathways. While blood cultures are the gold standard for pathogen identification, over-utilization leads to increased costs and potential false positives due to contamination. This study evaluated the clinical impact of implementing a host-response sepsis test (HRST), an FDA cleared laboratory-based assay designed for use in adult Emergency Department (ED) patients to determine its effect on blood culture ordering patterns and overall contamination rates. Methods We conducted a retrospective cohort study comparing approximately one year of pre-implementation data (July 2024–June 2025) to six months of post-implementation data (July 2025–December 2025) following HRST test go-live at a laboratory in Denton, Texas. Outcomes included: (1) blood culture utilization rate, defined as the proportion of ED encounters with blood cultures ordered; (2) contamination rate, defined as the proportion of patients with contaminated cultures among those with cultures ordered; and (3) contaminations per patient seen, defined as the proportion of ED encounters resulting in a contaminated culture. Between-period comparisons were performed using Pearson chi-square tests for equality of proportions (two-sided, a = 0.05). Results A total of 46,931 ED encounters were included in the pre-implementation period and 24,910 in the post-implementation period. Following the implementation of HRST, the proportion of patients receiving blood culture orders decreased significantly from 9.87% to 6.25% (a 36.70% relative reduction; p < 0.01). While the contamination rate per culture drawn showed a non-significant downward trend (7.28% to 6.56%; p = 0.34), the reduction in total culture volume led to a significant decrease in the total burden of contamination. Specifically, contaminations per patient seen dropped from 0.72% to 0.41%, representing a 42.98% relative reduction (p < 0.01). Estimated contamination savings were calculated by multiplying the contaminations per patient seen and subtracting the expected and observed contaminations. This resulted in an estimated 77 contaminations being saved in the 6-month post-implementation period. Conclusion Implementation of a host-response test for ED patients significantly improved laboratory stewardship by reducing unnecessary blood culture orders. Although the inherent contamination rate of the collection process remained stable, the overall frequency of contaminated results per ED encounter was nearly halved. These findings suggest that using HRST can streamline sepsis evaluations, lessen laboratory workload, and potentially reduce the downstream clinical costs associated with false-positive blood cultures.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

A-297 Impact of the Implementation of a Host-Response Sepsis Test on Blood Culture Utilization and Contamination Rates — Science Skim