B-003 Automation for the Isolation of Peripheral Blood Mononuclear cells (PBMCs) with Hamilton Robotics for T-Spot Testing

Kaelan Duncan, Connie La, Grace Gentile, Ethan Samaniego, Carlos Resureccion, Keene Huynh, Madilynn Vu, Leslie Lim

Key points

From the paper's conclusion
  • Conclusion The standard method for the isolation of PBMCs for T-Spot TB testing utilizes centrifugation to create a density gradient.

Abstract

Background Tuberculosis (TB), worldwide, remains to be the second leading infectious killer. Since 2023, the World Health Organization (WHO) reports that the TB response shows a significant recovery from the recent surge of cases with more diagnosis and treatment services provided with development of new methods to detect TB. T-Cell Select is the cell isolation step of the T-Spot test that enriches the desired population of peripheral blood mononuclear cells (PBMC) from whole blood collected using routine phlebotomy. The study uses the T-Cell Select reagent kit that selects targeted immune cells with magnetic bead-based cell separation. With the help of the Hamilton liquid handler to perform the preparation of cells for the T-Spot test, the process is simplified with increased accuracy and performance. Objective The objective of this study is to automate the method separating PBMCs from whole blood samples using magnetic bead reagent with the Hamilton automated liquid handler, in order to process large batch volumes of sample and increase efficiency and accuracy of T-cell spotting for Mycobacterium tuberculosis detection. Methods 1080 µL master mix consisting of DI water, buffer, Antibody 1, Antibody 2, and D-PBS was made and thoroughly mixed with whole blood sample before 64 µL magnetic beads were added. Cell isolation was then conducted using RPMI and the removal of supernatant. The PBMCs were then further isolated using AIM-V, and the WBC count was analyzed using the Sysmex Hematology Analyzer. Mixing and cell isolation was automated using the Hamilton Microlab STAR Liquid Handler. Results The method analysis of the automated bead reagent isolation of PBMCs was done with white blood cell count (WBC-BF). WBC count was determined to be above acceptable concentration value of 2.0 x 10^3 WBC/µl using the Sysmex hemocytometer for all 22 samples that were ran. A level of 2.0 X 103 is necessary for the T-Spot assay. Conclusion The standard method for the isolation of PBMCs for T-Spot TB testing utilizes centrifugation to create a density gradient. By automating this test using Hamilton Robotics, samples can be run in larger quantities in a shorter time and yield more accurate results due to purer extraction product. The Hamilton Robotics method isolates the WBCs using magnetic beads that bind to the antibodies, isolating WBCs without any other unwanted blood components. The study yielded a WBC-BF above the accepted value of 2.0 x 10^3 WBC/µl in blood. An increase in whole blood or binding beads used for testing could produce more favorable results. Next steps would be to run the whole automated method and compare against the centrifugation method.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers