A-396 Beyond the “Meter Disinfected” Button: A Proactive Quarterly Audit Approach to Glucometer Disinfection For Patient Safety

Melissa Shoemaker, Dawn Smith, Nichole Korpi-Steiner

Observational

Key points

From the paper's conclusion
  • Documenting “meter disinfected” in the glucometer does not necessarily reflect disinfection practices, and quarterly visual audits provide only a snapshot of performance.

Abstract

Background Sharing of point of Care (POC) glucometers between patients carries a high-risk for potential bloodborne pathogen transmission. Between 2008-2019, there were fifteen Hepatitis B (HBV) outbreaks in long-term care facilities associated with glucometers according to the Centers for Disease Control and Prevention, and evidence of HBV transmission between two residents linked to shared glucometers in 2024 despite established disinfection protocols. Mitigation efforts include training and monitoring of operator adherence with glucometer disinfection practices for patient safety. The aim of this observational study is to compare entry of a “meter disinfected” comment on the glucometers upon patient result verification versus quarterly visual inspection of glucometer cleanliness (dubbed “blitz”) as quality indicators for monitoring operator adherence with glucometer disinfection practices. Methods Inclusion criteria included trained operators of StatStrip glucometer (Nova Biomedical, Waltham, MA) testing who performed routine patient testing within 76 units at the University of North Carolina Medical Center (UNCMC). Comments entered in glucometers were automatically transmitted to the Telcor data management system (TELCOR, Inc., Lincoln, NE) upon device docking. Retrospective monthly % disinfection rate using the “meter disinfected” comment = (# “meter disinfected” comment entries/total patient tests)*100 was monitored between July 2024 – June 2025 and communicated with unit leadership. Prospective quarterly % disinfection rate = (# clean glucometers/total audited glucometers)*100 was monitored by visual inspection of glucometer cleanliness by POC, Infection Prevention, and Accreditation members in March, May, August, and November 2025. Audit findings were communicated with unit leadership quarterly and reeducation was provided upon request. Results During July 2024 – June 2025, the monthly mean % disinfection rate for UNCMC using “meter disinfected” comment was 89% (monthly mean range 86-91%). An average of 149 (∼70% of total) glucometers were visually inspected during each glucometer disinfection blitz. The % disinfection rate was 79%, 90%, 83%, and 87% over the 4 quarters. During audits, = 3 bloody glucometers were found in 5 units with recurrence of = 3 bloody glucometers in 3 units. In May 2025 both methods of monitoring % disinfection rate were performed yielding discordant findings. Notably a unit with 7 bloody glucometers (50%) documented “meter disinfected” comments for 90.3% results reported, and 8 units with no findings of bloody glucometers documented “meter disinfected” comments for <85% results reported. Conclusion Monitoring approaches for adherence with glucometer disinfection practices have limitations as highlighted by the discordant % disinfection findings. Documenting “meter disinfected” in the glucometer does not necessarily reflect disinfection practices, and quarterly visual audits provide only a snapshot of performance. Our transition to a visual audit model for % disinfection of glucometers moves patient safety from a clerical task to a clinical reality. By “blitzing” the facility quarterly, we have created a high-visibility culture of accountability that identifies focused areas for performance improvement and supports safer POC testing environments for mitigation of healthcare associated infections.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

A-396 Beyond the “Meter Disinfected” Button: A Proactive Quarterly Audit Approach to Glucometer Disinfection For Patient Safety — Science Skim